Self-levelling cross laser
Article no. 81145
Operating instructions
Intended use
Self-levelling cross lasers are instruments
for the determination of vertical and horizon-
tal lines in the do-it-yourself sector. It can be
used in internal zones.
This instrument is not intended for commer-
cial applications.
Specific safety instructions for
lasers
Do not look into the laser beam!
according to EN 60825-1:2007
•
ATTENTION: Avoid direct eye contact
with the laser beam. We recommend the
use of laser goggles when operating the
laser.
• Make sure that the laser beam is not
reflected by objects.
• Do not look into the laser beam with
optical devices such as magnifiers.
• Never direct the laser beam on human
beings or animals. Keep children away
from the tool.
• Only use self-levelling lasers in
compliance with these operating
instructions.
• Self-levelling lasers do not include any
service parts. Repairs on the laser unit
may only be accomplished by
qualified specialists.
Environmental conditions
1. Only use device in internal zones
2. Ambient temperature: 0-40° C
Laser light
Laser category 2
P ≤ 1mW; λ = 650 nm
Scope of delivery
− Self-adjusting laser
− Geared column stand
− Base plate with 360° scale
− 2 microcells 1.5 V (AAA)
Inserting batteries
• Open the lid of the battery compartment
at the rear side of the device.
• Insert the batteries according to the
applied "+" and "–" markings, and close
the lid of the battery compartment.
• When replacing batteries, always replace
both batteries.
• Remove batteries if you intend to store
the self-levelling cross laser for a longer
period without using it. Leakage danger!
Attention: Do not dispose of old batteries in
the household waste but in appro-
priate collection points according to
the local provisions!
Description
1. Vertical laser outlet opening
2. Horizontal laser outlet opening
3. Cross laser spirit level
4. On/Off switch and transportation lock
5. Geared column stand
6. Stand spirit level
7. Hand crank
8. Base plate with 360° scale
9. Adjustable feet
10. Battery compartment lid
Technical data
Measuring range:
Self-adjustment period
Self-adjustment range
Accuracy
Stand level
Threaded connection of stand
10 m max.
< 7 sec
+/- 3°
+/- 1 mm/m
47.5 – 124 cm
5/8" x 11mm