2. Location
Recommended locations:
In the home:
• For enhanced protection:
- Place a detector in each room, avert using listed places to avoid.
• For basic protection:
- Place a detector on each floor.
- Place a detector close to sleeping areas
(for example, in the corridor leading to rooms; in the case
of a long corridor > 10m, place 1 detector at each end).
- Place a detector in each bedroom occupied by a smoker.
Kitchen
Dining
room
Lounge
In the room:
15-25
cm
Bedroom
Bedroom
Smoker
bedroom
Flat
• The detector should preferentially be at-
tached to the ceiling in the middle of the room.
Otherwise, attach it more than 20cm from any
obstacle (partition wall, beam, etc.) and over
60cm from any room corner.
• If this is impossible, attach the detector to
the wall at a distance of between 15 and 25cm
from the ceiling.
20 cm
• In the case of an angled ceiling, attach the
detector at a location between 20 and 90 cm
vertically below the highest point.
90 cm
Basic protection
Enhanced protection
- 9 -
Corridor
Bedroom
Bedroom
Lounge
Basement
House