1. Set the dial to
position.
2. Connect the red test lead to the
VΩ terminal and the black test
lead to the COM terminal.
Confirm "OL" is indicated on the
display, and then short-circuit
the tips of test leads to make
the indication zero. A buzzer will
sound.
3. Connect the test leads to the
both ends of the conductor un-
der test. If the resistance under
test is 30 Ω or less, the buzzer
will sound.
1. Set the dial to
2. Use the Range button to select
either 100μF or 1000μF.
3. Connect the red test lead to the
VΩ terminal and the black test
lead to the COM terminal.
4. Discharge capacitor.
5. Connect the test leads to the
both ends of the capacitor under
test.
6. The reading is displayed.
To avoid electrical shock:
DANGER
Never make measurement on a
circuit in which voltage over AC600V exists.
Do not use with the Battery Cover removed.
Keep fingers behind the guards and away from
test lead tips during measurements.
1. Set the dial to
position.
2. Connect the red test lead to
the A terminal and the black
test lead to the COM termi-
nal.
3. Turn circuit power off, discon-
nect the circuit, connect the
test leads in series with the
circuit under test, and then
turn circuit power on. The
reading is displayed.
Continuity
Capacitance
position.
AC Current
To avoid electrical shock:
DANGER
Never make measurement on a
circuit in which voltage over AC600V exists.
Do not use with the Battery Cover removed.
Keep fingers behind the guards and away from
test lead tips during measurements.
1. Set the Dial to
2. Connect the red test lead to
the A terminal and the black
test lead to the COM terminal.
3. Turn circuit power off, discon-
nect the circuit, connect the
test leads in series with the
circuit under test, and then
turn circuit power on. The
reading is displayed.
1. Set the dial to
2. Connect the K-type tempera-
ture probe to the input terminal.
The positive (+) side of probe
should be connected to VΩ.
3. Contact the probe sensor to the
object under test.
4. The reading is displayed.
Never connect the Temperature
WARNING
Probe to an energized circuit.
When the dial is set to , OL should
CAUTION
be displayed. If anything else is
displayed, something may be wrong with the
DMM. Stop using the DMM immediately.
Using Bar Graph Display
The bar graph is like the needle on an analog meter,
it updates much faster than the digital display. The
number of segments indicates the measured value
and is relative to the full-scale value of the selected
range.
HOLD Button
Data Hold Function - Freezes the value on the dis-
play. Press the HOLD button to freeze the reading.
The reading will be held regardless of subsequent
variation in input. HOLD is displayed with the read-
ing. To exit Data Hold mode, press the HOLD button
again or change the dial.
SMART HOLD: The meter will beep continuously
and the display will flash if the measured signal is
50 counts larger than the display reading. (However,
it can not detect across the AC and DC Voltage/
Current).
The Data Hold readings of maxi-
CAUTION
mum / minimum are released when
the DMM enters Sleep Mode.
6
DC Current
position.
Temperature
position.