Service:
Electronic
Demand
Time Features
and Service
ERROR CODE
DISPLAYED
ERR0,3
ERR04
ERR05
POSSIBLE DEFECT
• Control
ERR 01
• Motor
inoperative
• Wiring
harness or
connection
to switch
• Position
switch
• Control
ERR 02
• Position
switch
• Control
.Motor
inoperative
or wiring
harness
,Control
• Position
switch or
wiring
harness
• Control
To remove an error code: 1. Unplug transformer.
2. Correct defect.
3. Plug transformer in.
4. Wait for at least 6 minutes. Theerror code wi!! return if the reason for
the error code was not corrected.
Service:
Timer/Softener,
Service
Checkout
Procedure
If you are not getting soft water, and an error
code is not displayed, use the procedures below
to find the problem. First make the following
visual checks.
VISUAL CHECKS:
1. Is there electrical power to the outlet the water
softening system transformer is plugged into?
Z Is there sufficient salt in the storage tank?
3. Is the softener bypass valve directing water
for soft water service?
4. Is the valve drain hose open to the drain,
not more than 8' above the softener, and
unobstructed? If hose is above 8', see
page 8, step 4.
If you do not find a problem with the visual
checks, continue below.
i
CONTROL
DISPLAY
BLANK.
CONTROL SHOWS
WRONG TIME AND
DAY,AND/OR IS
FLASHING.
Check electrical
power to control
__ (outlet,
transformer,
power cable, all
connections).
Electricalpower was
off. Resetthe correct
time of day.
REPAIRAS
NEEDED
CONTROL
DEFECTIVE
Investigate reason for
power loss.
j
Do manual
diagnostics
to verify
proper
function.
CONTROL DISPLAY
SHOWS CORRECTTIME
AND DAY AND IS
STEADY.
Do manual
diagnostics.
17