ASSEMBLY OF THE SPECIAL FRAME
¡Make sure the device is not connected to the
electricity net!
The special frame has been designed to integrate the
plate used to cover the ventilators, so this plate should
be removed. In order to do so, please follow the
instructions:
1º. Detach the door of the device lifting the hinges out
2º. Unscrew the screws on the plate covering the
3º. Disconnect the switches of the ventilators. Please
4º. Take the switch out and place it in the special
5º. Connect the cables to the switch again, making
6º. Place the frame in the correct position, and screw
7º. Put the door back in its' place.
of its' interior shaft.
ventilators and take it out.
take note of how they are connected, as later on
they'll have to be reconnected.
Three position switch
Connection
Blue cable
Brown cable
Red cable
frame.
sure all cables are in the same position as
before.
into place with the included screws.
Position II
Position 0
Position I
37