11. Slide a 3/8" hose clamp onto the boom connecting hose.
Place the end of the hose through the conduit clamp
attached to the pump, then slide a second 3/8" hose
clamp onto the hose. Leave hose clamps loose for now.
See Figure 7.
12. Push the hose onto the hose adapter in the end of the
"On-Off" valve. Tighten the hose clamp around the hose
and adapter. See figure 7.
13. Position the valve and hose clamp up against the conduit
clamp. Slide the other hose clamp against the other side
of the conduit clamp. Tighten the hose clamp without
collapsing the hose. See figure 7.
14. Slide the small hose clamp onto the spray gun hose
and then push the hose onto the hose adapter on the
1/4" tee fitting. Tighten the hose clamp around the hose
and adapter. See figure 7.
15. Snap the spray gun into the clips on the front of the
tank. (The large clip holds the spray gun handle and
the small clip holds the wand.) Refer back to figure 6.
SMALL HOSE CLAMP
ON - OFF
SPRAY GUN
VALVE
HOSE
1/4" TEE
FIGURE 7
LARGER HOSE CLAMPS
BOOM
CONNECTING
CONDUIT
HOSE
CLAMP
ENGLISH
16. To connect the wire harness to the tractor, attach the red
wire to the positive post on the battery or to the "HOT"
connection on a tractor switch or ammeter. The brown
wire may be grounded or connected to the negative
battery post. See figures 8 and 9.
IMPORTANT: This sprayer should be connected to 12 volt
batteries only!
PUMP SWITCH
BROWN
FIGURE 8
PLUG
NEGATIVE PIN
FIGURE 9
6
QUICK COUPLER
RED
RED
BROWN
DANGER! Never allow negative pin on
plug to come in contact with positive "hot"
post on battery. Fire or explosion may
result!
12 VOLT TRACTOR BATTERY
+
BATTERY
POSITIVE
+
"HOT"
POST
NEGATIVE
POST