ASSEMBLY
− Unpack the device and check whether any of the elements have been damaged.
− Press the button (19) and open the container lid (20).
− Place the HEPA filter (23) in the inlet filter (24) and secure it by turning it clockwise. Then put the filter (24)
into the container (21) and fix it by turning it to the right - Fig. 2. Close the cover (13).
ATTENTION. Do not use the vacuum cleaner without filters (23, 24).
− In the brush (15), slide the lock button (28), remove the lock (29) and insert the roller (14) - Fig. 3.
ATTENTION. Do not use a vacuum cleaner with a brush (15) without a properly installed roller (14).
− The vacuum cleaner can be used in several configurations - Fig. 4.
• OPERATING VACUUM CLEANER
− Check whether the battery (5) is installed in the body (7) and whether it is charged.
− Make sure that filters (23, 24) are installed in the container (21).
− Assemble the vacuum cleaner according to your current needs - Fig. 4.
− The vacuum cleaner starts working after pressing the switch (2).
− The suction force can be adjusted using the button (4).
− The pipe (10) is equipped with a joint, which allows for easy vacuuming under furniture. To bend the pipe
(10), press the lock button (18).
− Monitor the filling level of the container (21). If the container (21) is half full, empty it (see EMPTYING
THE CONTAINER).
− To turn off the vacuum cleaner, press the button (2).
− After finishing work, the vacuum cleaner should be cleaned (see CLEANING AND MAINTENANCE).
NOTE
The roller (14) in the brush (15) rotates at a very high speed - to avoid damaging the cleaned surface,
do not leave the brush (9) in the same place for too long.
The brush (15) is equipped with an overheating protection function that can cut off power
to the roller drive (14) if it becomes blocked. In this case, turn off the vacuum cleaner and clean
the roller. Do not turn on the device until it has cooled down.
Do not cover the outlet holes in the body (7) while the device is operating.
• CLEANING AND MAINTENANCE
− Before any maintenance or repair work, turn off the device
− and disconnect them from the power supply.
− Correct operation of the device is guaranteed by regular cleaning (preferably after each use) of the filters
(23, 24) and the container (21).
− The casing, accessories and power cord should be cleaned with a soft, slightly damp cloth with a little
dishwashing detergent.
− Wipe the inside of the container (21) with a damp cloth.
WARNING. Do not immerse the device body (7) in water.
− Do not use any harsh cleaning agents for cleaning as this may damage the housing surface.
Filters (23, 24)
− The condition of the filters (23, 24) should be checked regularly.
− The HEPA filter (23) should be replaced periodically.
− The inlet filter (24) can be washed with water and dried thoroughly.
− Do not wash the HEPA filter (23) with water every time you clean it, only if it is very dirty. In this case,
dry it very thoroughly (at least 24 hours) before using it again.
NOTE
The HEPA filter (23) must be thoroughly dried before reuse. Do not use high temperature for drying
to avoid deformation of the material.
Filters (23, 24) are consumable elements and are subject to natural wear, therefore they are not
replaced under warranty.