4
0
4-1. Detection area
7.5 m
6
Top view
Multi Level
4
2
0
2
4
6
7.5 m
0
Side view
2.2 m
2.7 m
Pet Alley
Side view
0.8 m
1.2 m
[1] Loosen the fixing screw, if used.
[2] Slide the Main unit down.
[3] Rise the mirror up to the fixing position.
[4] Tighten the fixing screw as before.
[1], [4]
Specifications
5
5-1. Specifications
Detection method
PIR coverage
PIR zones
Detectable speed
Sensitivity
Remove lower area detection to avoid small animals.
Pet alley
Power input
Current draw
Alarm period
Warm-up period
Alarm output
Trouble output
Tamper output
LED indicator
Operation temperature
Environment humidity
International protection
Mounting
Mounting height
Weight
[1] Mounting screw (4 x 20 mm) x 2 [2] Fixing screw (3 x 12 mm) x 1
Accessories
[3] Area masking strips
• Specifications and designs are subject to change without prior notice.
• These units are designed to detect an intruder and activate an alarm control panel.
Being only a part of a complete system, we cannot accept responsibility for any damages or
other consequences resulting from an intrusion.
Contact information
Manufacturer:
OPTEX CO., LTD.
5-8-12 Ogoto, Otsu, Shiga, 520-0101 JAPAN
5
10
15
20
25
30
35
40 ft.
25 ft.
20
15
10
5
0
5
10
15
20
25 ft.
3
6
9
12 m
5
10
15
20
25
30
35
40 ft
3
6
9
12 m
5
10
15
20
25
30
35
40 ft
3
6
9
12 m
! Caution
The anti-blocking function
can not be used with the
pet alley setting.
[2]
[3]
Passive infrared & Microwave
12.0 m (40') 120°wide
Multi level : 40 zones
Pet alley : 18 zones
0.3 to 2.0 m/s (1' to 6'7"/s)
2.0℃ ( 3.6°F) at 0.6 m/s
9.5 to 16 V DC
30 mA max. at 12 V DC
2.0 ± 0.5 s
Approx. 60 s (LED blinks)
N.C/N.O. switchable, 28 V DC 0.1 A max.
N.C. 28 V DC 0.1 A max.
N.C. 28 V DC 0.1 A max.
Open when the cover is opened
[1] Warm-up
[2] Alarm
[3] Walk test end
[4] Blocking detection
-40℃ to +45℃(-40°F to +113°F)
95% max.
IP 54
Wall (Outdoor, Indoor)
Multi level : 2.2 to 2.7 m (7' 3" to 8'11")
Pet alley : 0.8 to 1.2 m (2' 7" to 4' )
195 g (6.88 oz)
Distributed by:
Inim Electronics S.r.l.
ISO 9001 Quality Management
certified by BSI with certificate number FM530352
Centobuchi, via Dei Lavoratori 10
63076 Monteprandone (AP), Italy
Tel. +39 0735 705007 _ Fax +39 0735 704912
info@inim.biz _ www.inim.biz
4-2. DIP switch settings
MW
PIR
Default
MW
PIR
4-3. Walk test
[1] Close cover
PIR
MW
NOTE
With the cover open, the tamper activates.
This enables the LED function, regardless of DIP switch [1] setting.
When the cover is closed, the Walk test timer starts and automatically returns
to the normal mode after 3 minutes.
If the unit is powered up with the cover closed, it will not enter walk test mode.
Open and close the cover once to activate the walk test timer.
Conduct a walk test at least once a year.
5-2. Dimensions
5-3. Compliance
Inim Electronics S.r.l. declares that QXI-DT-X5 complies with RE Directive 2014/53/EU.
Documents can be found on our website: www.inim.biz
Microwave emission Frequency and Power
QXI-DT-X5: 10.525 GHz
The following list indicates the areas of intended use of the equipment and any known
restrictions. For countries not included in this list, please consult the responsible
Spectrum Management Agency.
10.525 GHz:
QXI-DT-X5 also complies with EU radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20 cm between the radiator & your body.
- 2 -
DIP switch ON
OFF
[8]
Future use
Anti-blocking *
[7]
sensitivity
High
Low
[6]
Anti-blocking *
ON
OFF
[5]
Future use
[4]
See right for the PIR sensitivity
[3]
[2]
Alarm output
N.O.
N.C.
[1]
LED
ON
OFF
*
Objects moving nearly by the detector may affect
the correct operation of the anti-blocking.
[2] Walk test (3 minutes)
3
3
78(3.07)
12.51 mW e.i.r.p
Belgium, Denmark, Finland, Germany, Greece, Italy, Luxembourg,
The Netherlands, Spain, Sweden, Iceland, Norway, Switzerland
PIR sensitivity
Super High
High
Middle
Default
Low
[3] Walk test ends
3
LED flashes 5 times
59 (2.32)
Unit: mm (inch)