this solution. Do not rinse out the machine.

5. 4 IN-PLACE SANITIZATION

The In-Place Sanitization prior to starting the
machine may be performed, if needed, only as
f u r t h e r p r e c a u t i o n , i n a d d i t i o n t o t h e
Disassembled Parts Sanitization described
before, but never in lieu of it.
1 Prepare two gallons of a warm (45-
60°C, 120-140 °F) sanitizing solution (100
PPM available chlorine concentration or 1
spoon of sodium hypoclorite diluted with
two litres of water) according to your local
H e a l t h C o d e s a n d m a n u f a c t u r e r ' s
specifications.
2 Pour the solution into the bowl(s).
3 Using a brush suitable for the purpose,
wipe the solution on all surfaces protruding
a b o v e t h e s o l u t i o n - l e v e l a n d o n t h e
underside of the top cover(s).
4 Install the top cover(s) and operate the
unit. Allow the solution to agitate for about
two minutes. Drain the solution out of the
bowl(s).
5 Use fresh product to chase any
remaining sanitizer from the bowl(s). Drain
this solution. Do not rinse out the machine.

6 ROUTINE MAINTENANCE

Daily: inspect the machine for signs of product
leaks past seals and gaskets. If proper assembly
does not stop leaks around seals or gaskets,
check for improper lubrication, worn or damaged
parts. Replace parts as needed with original
spare parts from the supplier.
6. 1 MAINTENANCE (TO BE
CARRIED OUT BY QUALIFIED
SERVICE PERSONNEL ONLY)
Montly: clean all internal components, primarily
the condenser, using compressed air.
To clean these internal parts, unplug the unit or
switch off the 2-pole wall breaker, then remove
front panel (dispensing side).
Condenser fins are very sharp. Use extreme
caution when cleaning.
13