USEFUL FUNCTIONS: "DISABLE
It is recommended to know the following functions that the application
offers from the SENT CONFIGURATION screen and that allow a
more agile and comfortable configuration of the installation. These
buttons will be visible once a configuration submission has been
made:
DISABLE
The DISABLE
Bluetooth from one or more detectors once configured and before the
time set by default (2hours) or set in the configuration (ADVANCED
MENU) elapses.
This function makes the detectors already configured invisible
and allows you to view only the detectors that remain to be
configured and that maintain Bluetooth Active.
To turn off Active Bluetooth for one or more detectors, select those
detectors once you receive the CONFIGURATION SENT confirmation
and press "DISABLE
RESEND
The RESEND function is useful when, for some reason, you have
made an attempted configuration submission, but the configuration
submission has not completed successfully. In this way, a new
communication attempt can be made with that device without having
to locate it again or exit this screen.
This situation may occur, for example, once the configuration process
has started, if you have moved away from or changed your position
with respect to one of the detectors you intend to configure. Select
the detectors that have not been configured correctly and press
RESEND
Si este proceso no tiene efecto, pruebe a iniciar el proceso de
CONFIGURACIÓN DE LOS DETECTORES de nuevo.
TIPS
It is recommended to edit the names of the detectors to be able to
quickly identify them and speed up their location and configuration.
The appropriate time to perform this action may be when you have
visually IDENTIFIED these detectors during the setup process.
Try creating and saving several templates for different typical
situations, for example: HALLWAYS, WORK AREA, LANDING, etc.
This way, when you go to the installation, you can apply these
settings quickly.
ADDITIONAL SECURITY WITH "LOCK CODE"
The Code Lock function of the detectors (ADVANCED MENU)
provides additional security to prevent access to the detector
configuration by unauthorized persons or people outside the
installation.
If you activate the Lock Code, you must enter a 4-digit code.
Once the Lock Code is active, you must use this same code to access
any configuration parameter of this template and the detectors that are
associated with this configuration.
The use of this Code Lock is recommended for specific cases, for
example, to avoid possible situations of vandalism. It is recommended
that this Code Lock function be used prudently and, if used, also
remember and write down this code in a safe place, available to
authorized installation personnel.
IMPORTANT: After three (3) incorrect attempts to enter the lock
code, the application suggests that you contact the manufacturer
in order to retrieve the forgotten or lost code.
If you find yourself in this situation, please contact DINUY:
PROBLEM RESOLUTION
Cuando un detector y/o la App DINUY Configure dejan de funcionar
correctamente, revisar los posibles fallos y las soluciones sugeridas en
la siguiente tabla que le ayudarán a resolver el problema:
Problem
When I press
the location
button,
I cannot
locate all
the detectors
Lamps do
not turn off
according to
desired light
conditions
The lamps
don't go out
I locate
several
detectors, but
I cannot
visually identify
which one
I am looking for
Lamps
work
in reverse,
turning on
when they
should be off,
and off
when they
should
be on
When
I press the
IDENTIFY
button,
I cannot
locate all
the detectors
DINUY, S.A. Auzolan, 2, 20303, IRUN, SPAIN
function allows you to disconnect immediately Active
".
Telephone: + 34 943 627 988
Email: support@dinuy.com
Possible cause
Bluetooth active
time has been
exceeded
Mobile
Bluetooth
communication
not activated
Bad connection
Luminosity
parameter
not adjusted
correctly
Very high
ambient
temperature
The set
Timer time
is too long
The detector
trips
unexpectedly
You are
locating
a detector
that is not
directly visible
The Output
Polarity is
set in
reverse
RF
interference
www.dinuy.com
" and "RESEND"
Suggested Solution
Check that
the detector
you want to
activate shows
a blue LED on.
If not,
disconnect
the device
from the power
supply and
turn it on again.
Activate Bluetooth
communication
on your
mobile device.
Check the
connections
and follow the
instructions diagram
Check this
setting using the
DINUY CONFIGURE
App
Wait for the
ambient
temperature to
reduce and test
the detector
Reduce
the Timing time
and check
that the lamps
turn off after
the time
has elapsed
Stay out
of the coverage
area to
avoid false
activations
Modify
(decrease)
the sensitivity
in the settings
(BASIC MENU).
Press
the IDENTIFY
button and look
for the detector
that has a
flashing RED
LED inside
for 10 seconds
continuously.
Make sure
you change
the Output
Polarity
in the
ADVANCED MENU
Switch off
possible radio
sources during
the configuration
process.
For example,
in the case of Wifi,
it is advisable
to disconnect
both the router and
the mobile/tablet
module