1 Scope of delivery
For professional installation of the filter system the following parts are required:
  Filter cartridge (1) with hygienic cap and male thread for screwing into the filter head (2).
  Filter head (2) with female thread for mounting the filter cartridge (1), suitable for all filter
cartridge sizes with installation label. An Aquastop and two non return valves (inlet and outlet)
are installed in the filter head.
  Bracket (3) for mounting the filter cartridge.
The filter cartridge has to be ordered separately from the filter head. The bracket is included in
the scope of delivery of the filter head.
2 Technical Data
2.1 Dimensions und weights
Total height without bracket, max.
Total height with bracket
Connection height
1
Distance from floor
Installation length
Filter cartridge Ø
Weight of dry filter cartridge, approx.
Weight of wet filter cartridge, approx.
2.2 Operating conditions
Connection thread (intake/outlet)
Nominal flow
Working pressure range
Intake water pressure
Pressure loss at 30 L/h (8 US gallons/h)¹
Pressure loss at 60 L/h (16 US gallons/h)¹
2
Pressure loss at 180 L/h (48 US gallons/h)¹
Water temperature, min.–max.
Ambient temperature, min.–max.
Ambient temperature during transportation/storage, min.–max.
Typical capacity
Operating position
Minimum flushing volume
Sum iron and manganese content
Free chlorine
Retention of bacteria
Width of pores of ultrafiltration membrane
¹with a 1.5 m (59.06 inch) hose DN8 fitted to both the intake and outlet.
3 Usage and design
3.1 Assigned use
This BWT filter cartridge ...
  is only to be used for optimising cold water fulfilling the legal requirements for drinking water.
  protects against bacteria, cryptosporidium, giardia, protozoa as well as microplastics and
provides hygienically perfect water for cold water dispensers and ice cube machines.
  is only to be used with water without added carbonic acid.
FWC_NeuesDesign_blau.indd 10
FWC_NeuesDesign_blau.indd 10
A
mm (inch)
B
mm (inch)
C
mm (inch)
D
mm (inch)
E
mm (inch)
F
mm (inch)
kg (lb)
kg (lb)
L/h (US gal/h)
bar (psi)
bar (psi)
bar (psi)
bar (psi)
bar (psi)
°C (°F)
+4 to +30 (+39 to +86)
°C (°F)
+4 to +40 (+39 to +104)
°C (°F)
-20 to +40 (-4 to +104)
L (US gal)
L (US gal)
L (US gal)
mg/L (ppm)
mg/L (ppm)
% (log range)
µm
EN
TC200
360 (14
/
)
3
16
385 (15
/
)
3
16
306 (12
/
)
1
16
65 (2
/
)
9
16
125 (4
/
)
15
16
88 (3
/
)
7
16
0.8 (1.8)
1.3 (2.9)
TC200
/
" (BSP male)
3
8
180 (48)
2 – 8 (29 - 116)
> 1.2 (> 17.4)
0.10 (1.5)
0.15 (2.2)
0.60 (8.7)
8000 (2113)
vertical
3 (0.8)
< 0.2 (<0.2)
< 0.5 (<0.5)
99.9999 (log 6)
0.02
10