• The display will show the
measured value.
NOTE:
• Before connecting the probe and
test lead at lower voltage ranges,
the display may show erratic
readings. This is normal because
the meter is highly sensitive.
Once a connection is made, the
true reading will be displayed.
• "OL" indicated an over-range
situation in manual mode. A
higher range should be selected.
• In manual mode, select the
highest range first if the value
to be measured is unknown
beforehand and lower as needed.
• Millivolt range (mV) is only
available in manual range mode.
Resistance
WARNING! Risk of electric shock,
be sure all power to circuit is
off and capacitors have fully
discharged before measureing
87_5059340213873_BODNER_A6_IM_MULTI_V03.indd 25
87_5059340213873_BODNER_A6_IM_MULTI_V03.indd 25
EN Use
resistance.
• Insert the black test lead into the
COM jack.
• Turn the rotary switch to the Ω
position. Press "RAN" to switch to
manual range if needed.
• Connect the test probe and test
lead across the resistance for
measurement.
• The display will show the
measured value.
NOTE:
• "OL" indicated an over-range
situation in manual mode. A
higher range should be selected.
• If the resistance measured is
greater than 1 MΩ, the meter
may take a few seconds to get a
stable reading. This is normal for
high resistance measurements.
• When the leads are not
connected or when measuring
an open circuit, the display will
read "OL".