CAUTION
Danger of crushing
▶ Keep hands away from the
pressing attachment.
3
Press the start button and keep it
held down until the pressing
operation is complete.
Result
✓ After the pressing operation has been
completed, the roller drive returns to its
starting position. The pressing tool is
once more ready for operation.
Rectifying malfunctions
Fault
Pressing tool cannot be
started.
Pressing tool stops
moving.
54043197424101003 © 12-2023
968.393.00.0(02)
Cancelling the pressing
procedure
Result
✓ The roller drive in the pressing tool
Cause
Mains cable is not
connected.
Mains cable or mains
plug is defective.
Network failure
Press and hold release button.
returns to its starting position. The
pressing procedure must be repeated
for a complete press connection. The
pressing attachment must not be
removed or rotated at this time.
Action
▶ Connect the mains plug to the power
supply system.
▶ Have the mains cable and mains plug
examined at an authorised repair
shop and replaced if necessary.
▶ Release start button.
▶ Press and hold release button: roller
drive moves to its starting position.
▶ Check the pressfitting for tightness
and repeat the pressing operation if
necessary.