Fish Box Evacuation Pump
Robust Single Diaphragm Design
Features
Flexible installation
No filter required
Compact and simple design
Self-priming to 9.5ft (3m)
12V and 24V variants
Dry running capability
Connections for 1-1/2" (38mm) ID marine hose
Up to 5 US gpm (19 lpm) flow
Suction Lift: 9.5ft. (3m)
Performance Curve
10.15
(0.7)
8.7
(0.6)
7.25
(0.5)
Differential
5.8
Pressure
(0.4)
PSI (Bar)
4.35
(0.3)
2.9
(0.2)
1.45
(0.1)
Installation
The Jabsco Waste Pump is self priming up to 9.5ft. (3m).
Uses multi-positional ports for easy mounting of the pump.
If mounted vertically the motor should be above the pump head.
Use rubber grommets provided to absorb vibration.
Plumbing Connections: Use 1-1/2" (38mm) ID, non collapsible waste
type suction hose.
Connect the hose to inlet and outlet of pump using two stainless steel
hose clamps at both ends.
All suction connections must be airtight and free of sharp bends or re-
strictions.
WARNING: The discharge thru-hull may be posi-
tioned below the waterline only if the discharge
hose has a vented loop at least 8" (20cm) above the
waterline at all angles of heel or trim.
WARNING: Do not pump gasoline, solvents, thinners
or other flammable liquids with flash point below
100°F (37.8°C). To do so can cause an explosion
resulting in injury or death.
Operation
The DC motor is suitable for intermittent duty and should not be run for more
than 30 minutes continuously.
1.32
2.64
(5)
(10)
Flow – US GPM (LPM)
2
3.96
5.3
(15)
(20)
6.6
(25)

Publicidad

loading

Este manual también es adecuado para:

Jabsco 50900-1000 jabsco 50900-1100