Main Components
1 - Transformer
2 - Transformer connection terminals
3 - 1.6A accessories Fuse
4 - Endpoint connection terminal
5 - 1.6A line fuse
6 - 230V A.C. control board power terminals
7 - Terminals for connecting accessories and command and control systems
8 - Electro-block connection terminal board
9 - Stop/Go lights connection terminal board (optional)
Electrical connections
L-N
230V A.C. power supply, 50/60Hz frequency
+ E -
Endpoint
L1T-L2T Transformer
10-11
Terminals to power accessories (24V A.C. - 500mA)
1-2
Stop Button (N.C. Contact)
2-3
Clockwise activating button (N.O. contact)
EbA EbA EbI EbI
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
2-4
Counter-clockwise activating button (N.O. Contact)
2-EM
Emergency button (N.C. contact)
2-S1
Anti-intrusion photocell (N.C. contact)
2-S2
Pressure sensor (N.C. contact)
+ -
Buzzer
Electroblocks