Indicator status:
Plug manual box to 5 pin socket, RED indicator, the power indicator on
Green indicator, the manual box switch indicator off, input off; green indicator on, input start (the value rotating value
potentiometer reads is the same as the ones of smoke and wind volume).
Yellow indicator, the manual box timing switch indicator, on, timing switch on; Yellow indicator off, timing switch off.
Volume setting of smoke and wind: once press "CONTRAL", rotating value potentiometer will get the value of the
smoke and wind, showed in the LCD.
Timing rang setting: 15 secs fixed timing. Intervals controlled by rotating interval potential.
Value output of the smoke and wind: when temperature comes to a certain point, input can be closed or opened by
pressing manual.
4. SWITCH ON/OFF Mode display
SWITCH OFF OK
In working status, press "OK" to enter into "SWITCH OFF", while LCD off. STANDBY indicator turns on red light and
other indicators, heating bar, electromagnetic pump and fans turn off.
In SWITCH OFF status, pressing "OK" for 2 secs, then enter into working status the whole process of which is to show
the version information, then self checked, eventual start to work.
Notes: When changing modes, first you need to close output function (including smoke and wind input); then press
"OK" if you want to start output function.
In any mode, it is from small to big volume to spray the smoke.
Every technology parameter will be remembered independently.
Heating lasts 8 minutes while utmost smoke volume keeps 1 minute.
4.- Trouble resolving:
1.Over heating resolving: when fogger machines' temperature surpasses the maximum permitting point, the system will
be in self protection, that is, heating system closes, utmost smoke volume to cool the machine, and "READY" flickers
to alarm.
Power surge reason:
i).Now keeps the fogger machine spraying above 6 seconds or after it begins to spray water, turn off power and check
whether the thermal fuse is loose.
If happens, connect to the new power supply.
(b) If not, the adjustable potentiometer is turned too down. You can apply test menu: when the LCD shows normally,
press "SHIFT" for above one second, then pressing "MENU" and test menu shows.
Ch0:xxx
Adjusting resistance value of the potentiometer to keep the parameter in a reasonable rang, in the process of which,
to change the voltage of thermal fuse to approximate 10.5mW in virtue of multimeter, value of Ch0, almost 175, when
"READY" indicator will be on. After fogger machine spray smoke several times until the temperature is too low to spray
any more, check Ch0. if the value is almost 175, problems are resolved; if not, adjust potentiometer again.
Now, press "SHIFT" for more than 1 second, then press "MENU" to enter in to testing menu. If you cannot enter into
testing menu, it is possible that thermal fuse has been broken. Change the thermal fuse in room temperature, then
power fogger machine again and check its value, voltage etc.
Note: the above processed by professionals.
(2) Less fluid resolution: When the fluid level is lower than the permission, fogger machine will alarm and the interface
jus like this:
In this case, fogger machine will not spray the smoke even you press the spray button in normal temperature unless
unique liquid is added.
TR-MQ 1500
English
Pag. 5