See
the
table
"
X" bottom of
canopy to
cooking surface
IMPORTANT:
Minimum distance "X": 24" (61 cm) from electric cooking surfaces.
Minimum distance "X": 30" (76.2 cm) from gas cooking surfaces.
Stainless Steel Hood Spacer Installation
•
You can elongate 1.5" (3.8 cm) of your range hood width
(¾" [1.9 cm] per side), installing the stainless steel spacers
included with your range hood.
•
Unpack the spacer and take off the protective.
•
Put each one on the right and the left side
•
Fasten hood spacer using three 4 x 8 mm screws to the
hood cabinet and tighten securely.
•
If cabinetry designs reduces the width opening (i.e.– 34.5"
or 46.5") to install the hood, the spacers are not used.
•
If you have a Full width opening (i.e. – 36" or 48")
to install the hood, you should use the spacers.
8
INSTALL HOOD INTO CABINET
The range hood attaches to the hood cabinet using four
mounting screws and washers.
NOTE: Hood cabinet must be capable of supporting 75 lb
(34 kg).
Prepare Range hood for mounting into cabinet
1.
2. Using a ⅛" (3 mm) drill bit, drill the 4 holes.
Hood insert cabinet
must be capable
of supporting
75 lb (34 kg)
PINAR628SS
PINAR634SS
PINAR140SS
3. Mark the cutout for the rectangular clearance hole for the
4. Using a jigsaw or keyhole saw, cut out the rectangular
Hood spacer
PINAR628SS
PINAR634SS
PINAR140SS
Install the range hood into the hood cabinet
1.
2. Determine the location where the power supply cable will
3. Drill a 1¼" (3.2 cm) hole at this location.
4. Pull enough power supply cable through the wall to allow
5. Remove terminal box cover and set aside.
6. Install the 10" (25.4 cm) square x 10" (25.4 cm) round
Mark the locations for the four mounting screws on the
hood cabinet as shown below.
Wall
E
D
MOUNTING HOLE DIMENSIONS
Model
DIM A
DIM B
10
⁄
"
1
1 6
6" (15.5 cm)
(25.6 cm)
upper range hood motor housing as shown.
clearance hole for the upper range hood housing.
Wall
D
UPPERHOOD MOTOR HOUSING DIMENSIONS
Model
DIM A
DIM B
4
⁄
"
15
1
4
(10.8cm)
(38.9 cm)
Determine and make all necessary cuts in the wall or
roof for the vent system. Install the vent system before
installing the cabinet hood insert. See the "Venting
Requirements" section.
be run through the wall.
for easy connection to the terminal box.
vent transition with damper to top side of the
range hood, using 4 - 3.5 x 9.5 mm screws.
A
B
C
DIM C
DIM D
DIM E
12
1
⁄
"
24
1
⁄
"
6
3
(30.9 cm)
(61.8 cm)
Ø
⁄
1
8
(3mm)
14
⁄
"
29
⁄
"
15
13
1 6
1 6
(38 cm)
(75.8 cm)
A
B
C
DIM C
DIM D
11
⁄
"
22
⁄
"
7
13
1 6
1 6
(29 cm)
(58 cm)
⁄
"
5
1 6
14
⁄
"
28
⁄
"
1
15
2
1 6
(36.8 cm)
(73.5 cm)
"