Descargar Imprimir esta página

PRODIS HC610RSS Manual De Instrucciones página 9

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
Operation
Temperature Setting and Control (Dixell)
The front panel of the thermostat
display:
1.
Defrost-/ Light Key (Light key only
active in glass door models)
2.
SET Key
3.
UP- Key
4.
Stand By-/ DOWN Key
How to switch the unit from Stand By Mode to ON mode / How to switch the unit from ON Mode to Stand By mode
• Press and hold the Standby key
How to see the set point
• Push and immediately release the
• Push and immediately release the
How to change the set point
• Push the
key for more than 2 seconds to change the set point value
• The value of the set point will be displayed and the "
• To change the set value push the "
• To memorise the new set point push the
Automatic defrost
• The appliance will automatically run defrost cycles.
Note: The defrost timer starts from the time the appliance is initially powered up.
Manual Defrost:
• Press and hold the "
" DEFROST button for 5s.
• The defrost cycle will start immediately and the Defrost LED illuminates.
Note: Starting a manual defrost resets as well the automatic defrost timer.
How to turn ON / OFF the light
• Press and release the
key, to switch the light ON or OFF.
Note: Light function is active only for glass door models.
How to see recorded MINIMUM and MAXIMUM temperatures
• Press and release the "
" or " " key. The recorded MIN ("Lo")/MAX ("Hi") temperature of the last 24h is displayed.
• To reset the record press
How to Lock and Unlock the keyboard
• Press both " " and " " key at the same time for more than 3s. The display shows "PoF"/ "Pon" to indicate that the keyboard is
locked/ unlocked.
Alarm Code Description:
• P1 – Room probe failure, P2 – Evaporator probe failure, HA – Max.temperature alarm, LA – Min. temperature Alarm, H2 – Max.
rd
temperature alarm 3
Probe, L2 – Min temperature alarm 3
alarm, HF – Defrost alarm.
P2M070STD-Ver1.0
LED
for 3s.
key, the set point is displayed.
key or wait about 15s to return to normal visualisation.
" starts blinking
" (up) or " " (down) arrows within 15s.
key again or wait for 15s.
for 3s while the MIN or MAX temperature is displayed.
rd
probe, EA – External Alarm, CA – Serious external alarm, dA – Door open
8
Mode
Function/ Explanation
ON
Compressor Operation Indicator
Flashing
Compressor Start Delay Indicator
ON
Defrost enabled
Flashing
Drip time in progress
ON
Fan Operation Indicator
Flashing
Fan Delay Indicator (After Defrost)
ON
Alarm Indicator
ON
Light Indicator (active on glass door)
ON
Measurement Unit Indicator
Flashing
Programming Mode
Stand By Mode (Compressor OFF, Light and
ON
fan function with normal operation)
GB

Publicidad

loading

Este manual también es adecuado para:

Hc410fssHc410rss