TROUBLE
Sprayer will not turn on when
Power Button is pressed (no
audible hum of the pump.)
Sprayer turns on (audible hum of
pump heard) but will not spray.
Sprayer turns on but only sprays
at low pressure.
Hose Leaks at Tank connection.
Hose Leaks at Shut-off.
Nozzle drips when Shut-off Lever
is released.
Nozzle Tip leaks
TROUBLESHOOTING
LOOK FOR
1. Battery not charged. Light
does not turn ON.
2. Pump is damaged, over
heated, or non-functional. Visual-
ly inspect the Pump for damage.
Use the Charger to diagnose any
Battery problem. See Charging
the Pump Internal Battery.
3. Tank is already pressurized so
the Pump has turned off auto-
matically.
4. Pump is connected to Charger.
1. No liquid in Tank.
2. Shut-off clogged.
3. Nozzle clogged.
4. Pump is not tightened to Tank,
leaks at Seal.
1. Tank not yet pressurized.
2. Air leaking from Tank at Seal.
3. Tank Seal or Seal surfaces are
damaged.
4. Shut-off clogged.
5. Nozzle clogged.
1. Cracked, swollen or faulty
Hose.
2. Damaged connection.
1. Cracked, swollen or faulty
Hose.
2. Damaged connection.
1. Dirt or debris in Shut-off.
2. Damaged O-Ring or Seal in
Shut-off.
1. Flat Seal missing.
2. Flat Seal damaged.
REMEDY
1. Charge Pump if no light is ON.
See Charging the Pump Internal
Battery.
2. Replace Pump if damaged or
non-functional. Allow Battery to
cool if overheated.
3. Open the Shut-off (depress
Lever) to see if the Sprayer starts
spraying.
4. Disconnect Charger.
1. Add liquid to Tank. See Filling
the Sprayer.
2. Clean Shut-off. See Shut-off
Maintenance.
3. Clean Nozzle. See Nozzle
Maintenance.
4. Tighten Pump to Tank.
1. Allow time for Pump to
pressurize Tank (at least to 20
seconds).
2. Tighten Pump to Tank.
3. Replace Tank Seal.
4. Clean Shut-off. See Shut-off
Maintenance
5. Clean Nozzle. See Nozzle
Maintenance.
1. Replace Shut-off Assembly.
2. Replace Shut-off Assembly.
1. Replace Shut-off Assembly.
2. Replace Shut-off Assembly.
1. Clean Shut-off Assembly.
2. Replace Shut-off Assembly.
1. Install Flat Seal behind Nozzle
Tip. See Assemble Wand, Shut-off
and Nozzle.
2. Replace Flat Seal.