Operation Guide
4-Wire Settings
After connecting two hubs using a network cable, select 4 Wire > Line Sequence
Switching on the hubs, and then select Standard on one hub and Cross on the
other hub.
Hub Display
Select 4 Wire > Line Sequence
Hub ①
Switching .
4-Wire Settings
Select 4 Wire > Line Sequence
Hub ②
Switching .
4-Wire Settings
Two-System Cascaded Connection via the IP Network
Use a standard network cable to connect two hubs via the RJ45 interface. Either of
the two RJ45 interfaces on the hub works. The length of the network cable is up to
300 meters.
4 Wire Setting
Input Gain
Output Gain
Line Sequence Switching
4 Wire Setting
Input Gain
Output Gain
Line Sequence Switching
Network cable of 300 meters
Network cable of 300 meters
EN-17
Select Standard.
Line sequence switching
3
4
5
6
Standard
IN+
OUT+
OUT- IN-
3
4
5
6
Cross
OUT+ IN+
IN- OUT-
Select Cross .
Line sequence switching
3
4
5
6
Standard
IN+
OUT+
OUT- IN-
3
4
5
6
Cross
OUT+ IN+
IN- OUT-