AXF-240
AMPLIFIER
4. REAR PANEL
1. Frame to GND link.
2. AC Power socket.
Power input from 115 to 230 Vac (50/60 Hz). The voltage is self-adjusting.
3. Fuse holder.
4. Speaker outputs.
100V, 70V and 4 Ω speaker output.
5. Line OUT output.
Plays all system audio. It is not affected by the Master volume.
6. Preamp In / Out (RCA connector).
Allows the connection of an equalizer or feedback suppressor. Connection between the preamp
and the amplifier.
7. AUX1 / AUX 2 RCA input.
Audio inputs with RCA connector. They include sensitivity adjustment control.
8. MIC1 / MIC2 / MIC3 / MIC4 / MIC5 XLR input.
Microphone input with or without phantom power. The is a contact for a priority call.
9. SURETY PAGING AUX RELAY.
This relay connects (change the state) when the speech preference is activated.
10. EMG input.
Priority emergency input over all the other inputs. It is not affected by Master volume control.
AXF-240_Manual_ENG_V1.0
Page 5 of 16