Descargar Imprimir esta página

AEG X81253MI1 Manual De Uso página 5

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
CONTROLS
The hood is fi tted with a control panel with
aspiration speed selection control and a
light switch to control cooking area lights.
Use the high suction speed in cases
of concentrated kitchen vapours. It is
recommended that the cooker hood suction
is switched on for 5 minutes prior to cooking
and to leave in operation during cooking
and for another 15 minutes approximately
after terminating cooking.
The control switches are located on the
hood's front panel:
O
1 2 3
A
B C D E F G
A. Main switch, hood off (OFF-stand-by).
B. Start and choice of motor speed 1-2-3-
1-2.........
C. Indicates speed 1 (LED).
D. Indicates speed 2 and saturation of the
grease fi lter (LED)
E. Indicates speed 3 and saturation of the
charcoal fi lter (LED) (fl ashing LED)
F. Indicates Intensive speed (LED).
G. Intensive speed on/off. The Intensive
speed runs for 5 minutes:
If the hood is on when the Intensive
speed is activated, the hood reverts to
previous speed after 5 minutes.
If the hood is off when the Intensive
speed is activated, the hood will be
turned off after 5 minutes.
To interrupt the Intensive speed, press
button A or B.
H. Light OFF
I.
Light ON
Should the hood or the controls fail to
operate: disconnect the power supply
for at least 5 seconds, then turn the
hood back on again.
Control device for grease and charcoal
fi lters
This hood is fi tted with a device that
indicates when maintenace of fi lters should
be done.
If the hood is to be used with a charcoal
fi lter, the saturation
indicator light must be enabled as follows:
Set "OFF" the hood.
i
O
H
I
Press buttons B and G simultaneously
and hold them for 3 seconds. At fi rst only
the grease fi lter LED D will light up, but
when the charcoal fi lter LED E lights up the
saturation indicator will be enabled.
To disable it: Press buttons B and G again
simultaneously and hold
them for 3 seconds, until the charcoal fi lter
LED goes out.
Grease fi lter LED (D)
LED D will start to fl ash when it is time to
clean the grease fi lter.
Cleaning will be necessary after 40
working hours. Always comply with the
maintenance instructions for the grease
fi lter.
Charcoal fi lter LED (E)
The charcoal fi lter LED E will start to
fl ash when the charcoal fi lter needs to be
replaced.
This operation is necessary after
approximately 160 working hours.
Resetting the saturation indicator
After cleaning or replacing the fi lters, press
button A for 3 seconds until the grease fi lter
LED D or the charcoal fi lter LED E stops
fl ashing.
LIGHTING
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs
ensure they are cooled down.
Replace with a new 12 Volt, 20 Watt
(Maximum) halogen light made for a G-4
base SUITABLE FOR USE IN OPEN
LUMINAIRES. Follow package directions
and do not touch new light with bare hands.
ENGLISH
5

Publicidad

loading

Este manual también es adecuado para:

Di 8610