Filter Assembly (for 3M™ Filters 5N11 and 5P71)
1. Place filter into 3M™ Retainer 501 *(07054) so printed side of filter faces the cartridge.
2. Press cartridge into filter retainer. It should snap securely into filter retainer. When correctly installed, filter should completely cover face of
cartridge (Fig. 3).
3. To replace filter, remove retainer by lifting on TAB.
In Brazil, the 3M™ Filter 5935BR is assembled following the same procedures as the 5N11 and 5P71.
3M™ Filter Adapter 502 Assembly and Filter Attachment
1. Align adapter over cartridge. Engage front snap by squeezing front of cartridge and adapter together, placing thumbs of both hands over top of
adapter and fingers along bottom sides of cartridge (Fig. 4).
2 Engage back snap by squeezing back side of cartridge and adapter together using the same hand positions. An audible click should be heard as
each snap is engaged (Fig. 5).
3. Place filter onto the filter holder so that filter comes into even contact with gasket. Twist clockwise a quarter turn until it is firmly seated and filter
cannot be turned further. Repeat for second filter.
NOTE: The 3M™ Filter Adapter 502, once installed on a 3M™ Cartridge 6000 Series, is not to be removed or reused. Removal or reuse may
result in leakage, overexposure, sickness or death.
3M™ Filters 2000 Series and 7093/7093C with 3M™ Filter Adapter 502
Place filter onto the filter holder so that filter comes into even contact with gasket. Twist clockwise one quarter turn until it is firmly seated and filter
cannot be turned further. Repeat for second filter.
NOTE: The 3M™ Filter Adapter 502, once installed on a 3M™ Cartridge 6000 Series, is not to be removed or reused. Removal or reuse may
result in leakage, overexposure, sickness or death.
Fig. 2
Fig. 3
Fig. 4
6
(English)
Fig. 5