  • Página 1 MANUAL DE INSTRUÇÕES INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES...
  • Página 3 ÍNDICE - PORTUGUÊS ESPECIFICAÇÕES ...................... 5 ACESSÓRIOS ......................5 APRESENTAÇÃO ....................... 6 INSTRUÇÕES DE OPERAÇÃO .................. 7 LIGAR / DESLIGAR ......................7 MEDIÇÃO ........................7 AJUSTE ........................... 9 FUNÇÕES ADICIONAIS .................... 11 MEMÓRIA INTERNA ..................... 11 CONFIGURAÇÕES ....................12 MANUTENÇÃO ......................14 CONTENTS - ENGLISH SPECIFICATIONS .....................
  • Página 5 (4500-Cl G, DIN Standard, ISO 7393/2) - Adaptação do método colorimétrico vermelho de fenol para medições de pH 2. ACESSÓRIOS Itens que acompanham o Cloro-pH Max: - 2 cubetas para medição (15mL) - 1 kit de reagentes para cloro livre, cloro total e pH - 1 flanela para limpeza/secagem das cubetas - 1 cabo USB para alimentação e comunicação com o PC...
  • Página 6 3. APRESENTAÇÃO VISTA SUPERIOR Tampa de medição Seta para alinhamento Compartimento de medição Visor Tampa do compartimento da bateria (embaixo) Botão On-Off Botão ▼ Botão ▲ Conexão USB (lateral) Imagem meramente ilustrativa VISOR LCD Tempo para Identificação da amostra - SID desligamento Identificação do Horário...
  • Página 7 ATENÇÃO: NUNCA UTILIZE bateria e o adaptador AC/DC ao MESMO TEMPO no instrumento, isto pode ocasionar danos irreversíveis ao circuito!  Para ligar o Cloro-pH Max, pressione brevemente o botão On-Off e aguarde pela inicialização;  Para desligar, no menu inicial, mantenha pressionado o botão On-Off. Aparecerá...
  • Página 8 18) Limpe e seque totalmente a parede externa da cubeta, utilizando uma flanela ou papel toalha macio; 19) Insira a cubeta no compartimento de medição do Cloro-pH Max, realizando o alinhamento da seta presente na cubeta com a seta localizada no compartimento de medição do instrumento;...
  • Página 9  Evite a entrada de líquidos no compartimento de medição, pois isso pode ocasionar danos irreversíveis ao circuito do instrumento. AJUSTE O Cloro-pH Max pode ser ajustado em 6 pontos de cloro e 5 de pH, respeitando a seguinte sequência: Cloro: 0ppm  0.5ppm  1.0ppm  2.0ppm  3ppm  5ppm...
  • Página 10 10) Com cuidado, feche a tampa de medição do Cloro-pH Max; 11) Para iniciar a leitura e ajuste, pressione o botão Medir. O instrumento iniciará o procedimento de análise do padrão inserido;...
  • Página 11 5. FUNÇÕES ADICIONAIS MEMÓRIA INTERNA O Cloro-pH Max armazena até 1000 registros na memória interna, sendo que é possível visualizar diretamente pelo medidor os últimos 50 registros armazenados. Para visualizar os demais registros da memória interna, realize o download de dados em um computador.
  • Página 12 6. CONFIGURAÇÕES ACESSO Para acessar as configurações, com o instrumento ligado, navegue até a opção Configs utilizando os botões ▲ e ▼ e pressione brevemente Entrar; Para retornar, mantenha pressionado o botão On-Off ou selecione no final do menu a opção Voltar. ...
  • Página 13 6. CONFIGURAÇÕES  Stand by: Ajusta o tempo para desligamento automático e/ou ativação do modo OFF - always on (quando alimentado via USB)  Utilize os botões ▲ e ▼ para alternar entre as opções OFF, 30s, 45s, 60s, 90s e 120s; ...
  • Página 14 Cloro-pH Max;  Evite quedas e/ou choques mecânicos, pois podem ocasionar danos irreversíveis ao instrumento;  Proteja o Cloro-pH Max de respingos d’água, a fim de evitar à entrada de umidade no circuito e danos ao instrumento. Cubetas ...
  • Página 15 7. MANUTENÇÃO DESCARTE DE BATERIAS E ELETRÔNICOS Este produto contém bateria e componentes eletrônicos. Não os elimine com outros resíduos domésticos comuns. Entregue- os no ponto de coleta apropriado conforme orientações locais. Importante: o descarte correto de eletrônicos e baterias evita consequências negativas para...
  • Página 17 AKSO PRODUTOS ELETRÔNICOS ● www.akso.com.br vendas@akso.com.br (51) 3406 1717 Acesse a página do produto no site da Akso e verifique se a versão do seu manual está atualizada.
  • Página 18 Cl G, DIN Standard, ISO 7393/2) - Adaptation of the phenol red colorimetric method for pH measurements 2. ACCESSORIES Items that comes with Cloro-pH Max: - 2 glass cuvette (15mL) - 1 reagent kit for free chroline, total chroline and pH...
  • Página 19 3. PRESENTATION UPPER VIEW Measuring cap Alignment mark Measuring compartment Display Battery cap (behind view) On-Off button Button ▼ Button ▲ USB connection (side view) Imagem meramente ilustrativa LCD DISPLAY Sample ID - SID Time to shutdown Hour User ID - UID Parameter Measurement value Measurement unit...
  • Página 20 May cause irreversible damage to the device.  To turn on Cloro-pH Max, press briefly the On-Off button and wait for initialization.  To turn off, on the home menu, hold on the On-Off button. Will appear Turn off device?, press the Yes button to confirm.
  • Página 21 18) Clean and dry the outer wall of the cuvette using a cleaning wipe or a soft paper towel; 19) Insert the cuvette in Cloro-pH Max’s measurement compartment, aligning the arrow on the cuvette with the mark located on the instrument’s compartment;...
  • Página 22  Prevent liquids from entering the measurement compartment, because this can cause irreversible damage to the circuit. ADJUST Cloro-pH Max can be adjusted in 6 points of chlorine and 5 of pH, respecting the following sequence: Chlorine: 0ppm  0.5ppm  1.0ppm  2.0ppm  3.0ppm  4.0ppm...
  • Página 23 9) Holding the cuvette by the lid carefully insert it in the measurement compartment, aligning the cuvette body indication with the instrument alignment mark. 10) Carefully close Cloro-pH Max’s measurement lid; 11) To start the adjustment and reading, press Meas.
  • Página 24 5. ADDITIONAL FUNCTIONS INTERNAL MEMORY Cloro-pH Max stores up to 1000 records in the internal memory, it is possible to view the last 50 records stored directly in the instrument. To view the others records in the internal memory, it is necessary to download the data to a computer.
  • Página 25 6. SETTINGS ACESS To acess the settings, turn on the instrument, browse to the Settings option using ▲ and ▼ buttons and press briefly Enter. To return, hold on the On-Off button or select in the menu the Back option and press Enter button.
  • Página 26 6. SETTINGS  Stand by: Adjust the time to the automatic shutdown and/or activation of OFF – Always on (when powered by USB).  Use the ▲ and ▼ buttons to switch between OFF, 30s, 45s, 60s, 90s and 120s options; ...
  • Página 27 Cloro-pH Max circuit;  Avoid falls and/or mechanical shocks, as they may cause irreversible damage to the instrument;  Protect Cloro-pH Max from splashing water in order to prevent moisture from entering the circuit and damaging the instrument. Cuvettes ...
  • Página 28 7. MAINTENANCE BATTERY AND ELECTRONICS DISPOSAL This product contains a battery and electronic components. Do not dispose of them with other common household waste. Please deliver them to the designated collection point as per local guidelines. Important: Proper disposal of electronics and batteries prevents negative consequences for the environment and, consequently, for human health! For more information about the service and/or waste disposal...
  • Página 29 AKSO PRODUTOS ELETRÔNICOS ● www.akso.com.br vendas@akso.com.br (51) 3406 1717 Go to the product page on the Akso website and check if your manual version is up to date.
  • Página 31 (4500-Cl G, DIN Standard, ISO 7393/2) - Adaptación del método colorimétrico rojo de fenol para mediciones de pH 2. ACCESSORIOS Artículos que acompañan el Cloro-pH Max: - 2 cubetas para medición (15mL) - 1 kit de reactivos para cloro libre, cloro total y pH - 1 franela para limpiar/secar las cubetas - 1 cable USB para alimentación y comunicación con el PC...
  • Página 32 3. PRESENTACIÓN VISTA SUPERIOR Tapa de medición Flecha de alineación Compartimiento de medición Pantalla Tapa do compartimiento de batería (abajo) Botón On-Off Botón ▼ Botão ▲ Conexión USB (lateral) Imagem meramente ilustrativa PANTALLA LCD Tiempo de apagado Identificación de automático muestra - SID Identificación de Horário...
  • Página 33 ATENCIÓN: NUNCA USES batería y el adaptador AC/DC al MISMO TIEMPO en el instrumento, esto puede ocasionar daño irreversible al circuito!  Para encender el Cloro-pH Max, presione brevemente el botón On-Off y esperar a la inicialización;  Para apagar, en el menu inicial, mantener presionado el botón On-Off.
  • Página 34 4. INSTRUCCIONES DE OPERACIÓN Análisis de cloro libre 13) Abra la tapa del instrumento y retire la cubeta del compartimento de medición 14) Retire la tapa de la cubeta con la muestra utilizada en la puesta a cero; 15) Agregue 3 gotas de reactivo DPD 1 a la muestra, luego 3 gotas de reactivo DPD2 sosteniendo los frascos de reactivos en posición vertical mientras agregas las gotas;...
  • Página 35  Evite que entre líquidos en el compartimento de medición. AJUSTE El Cloro-pH Max puede ser ajustado en 6 puntos de cloro y 5 de pH, respetando la siguiente secuencia: Cloro: 0ppm  0.5ppm  1.0ppm  2.0ppm  3.0ppm  4.0ppm...
  • Página 36 10) Con cuidado, cierre la tapa de medición del Cloro-pH Max; 11) Para iniciar la lectura y el ajuste presione el botón Medida el instrumento iniciará...
  • Página 37 5. FUNCIONES ADICIONALES MEMORIA INTERNA El Cloro-pH Max almacena hasta 1000 registros en su memoria interna, y és posible ver directamente por el medidor los ultimos 50 registros almacendos. Para ver los otros registros en la memoria interna, es necesario descargar los datos a una computadora.
  • Página 38 6. CONFIGURACIONES ACESSO Para accedar a las configuraciones, con el instrumento encendido, navegue a la opción Configs usando los botones ▲ y ▼ y presione brevemente Entrar; Para regresar, mantenga presionado el botón On-Off o seleccione la opción Atras al final del menu y presione el botón Entrar. ...
  • Página 39 6. CONFIGURACIONES  Stand by: Ajusta el tiempo para apagado automático y/o la activación del modo OFF – Always on (cuando se alimenta a través de USB).  Use los botones ▲ y ▼ para cambiar entre las opciones OFF, 30s, 45s, 60s, 90s e 120s;...
  • Página 40 1) Debajo del Cloro-pH Max, quite el tornillo de fijación de la tapa, utilizando un destornillador Philips; 2) Desenganche la cubierta del instrumento con cuidado;...
  • Página 41 7. MANTENIMIENTO DISPOSICIÓN DE BATERÍAS Y DISPOSITIVOS ELECTRÓNICOS Este producto contiene batería componentes electrónicos. No los deseche junto con otros residuos domésticos comunes. Llévelos al punto de recolección adecuado siguiendo las indicaciones locales.. Importante: Importante: La correcta disposición de los dispositivos electrónicos y las baterías evita consecuencias negativas para el medio ambiente y, por ende, para la salud humana.
  • Página 42 AKSO PRODUTOS ELETRÔNICOS ● www.akso.com.br vendas@akso.com.br (51) 3406 1717 Accede a la página del produto en el sítio web de Akso y averigüa si la versión de su manual esta actualizada.