5.2
Wire in the apparatus according to the electrical supply required by the actuator (see label on product),
following the table below.
0
1
2
3
ch 1
Dip-switch 2
s.1
Pos.1
s.2
Pos.2
s.3
Pos.3
s.1
Pos.1
s.2
Pos.2
s.3
Pos.3
s.1
Pos.1
5.3
s.2
Pos.2
Press the control button and close the window, checking that:
s.3
Pos.3
a.
s.1
Pos.1
frame is bigger than or equal to 0 mm. If necessary, insert spacers so as to obtain the correct gap.
s.2
Pos.2
b.
s.3
Pos.3
by using the screws and slots.
Having reached the correct closing position, press the control button and open the window in order to check
that the actuator runs freely over the full travel set up.
Having achieved the required opening run, press the control button again to close the window. Once the window
has completely closed, check that the screws, supports and fixings are tightened correctly, and that the seals
are sufficiently compressed.
12
Electrical connection
Yellow/Green
Earth
Blue or Gray
Neutral / Common
Black
Phase / Open
Brown
Phase /Closed
Operating test
The window is completely closed. If it is not, check that the gap between the window and the
The spindle is perfectly perpendicular to the window frame. If necessary adjust the fixing bracket
230VAC supply
Electric 230VAC wiring
0
1
2
3
N
110/230V~ 50/60Hz F
4
4
4
5
5
5
6
6
6
0
1
2
3
N
110/230V~ 50/60Hz F
Installation completed
1
2
+
24 Vdc
-
4
4
4
5
5
5
6
6
6
1
2
+
24 Vdc
-