OPERATION INSTRUCTIONS
LIGHTING INSTRUCTIONS
Warning: Always light your smoker with both doors open.
CAUTION: If the flame extinguishes accidentally during ignition or operation,
immediately TURN OFF the cylinder valve and then TURN OFF the control knob.
Igniter Lighting System
1. Check all connections for leaks using the "soap water" test as explained on page 16
for "checking for leaks."
2. Open both of the smoker cabinet doors. Always keep the doors open during lighting.
3. Check for any blockage to each venturi tube or burner, damper setting, and ventilation setting.
Remove any foreign objects or matter.
4. Be sure the burner control knobs are in the
"OFF" O position.
5. Open the LP cylinder valve by turning
counterclockwise
6. Push igniter
on the control unit down 3 to
4 seconds while turning the left control knob to
"HIGH" .. Once the burner is lit, repeat this step
for the burner on the right.
7. If ignition does not take place within 5 seconds, immediately turn both control knobs to "OFF" O.
Wait 5 minutes and repeat above steps 6 and 7.
8. If burner still fails to light, try match lighting using the instructions on page 21.
9. Once the burners are lit, close the doors to allow heat to accumulate. The smoke stack
on the top of the smoker can be adjusted to the desired setting to allow proper ventilation
and combustion. NEVER CLOSE THE SMOKE STACK COMPLETELY.
.
20