Descargar Imprimir esta página

Fulgor Milano FUGMO 4505 MT MBK Instrucciones Para La Instalación Y El Uso página 38

Ocultar thumbs Ver también para FUGMO 4505 MT MBK:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
16 - Electrical connection
EN
Before making the electrical connection, make sure that:
the characteristics of the electricity supply fulfil the
requirements indicated on the serial number plate fixed on the
front of the oven;
the electricity supply is earthed in accordance with current
laws and regulations. Earthing is required by law. The cable
should not, at any point, exceed 50°C above room temperature.
This oven must be connected to the power supply with the power
cable and a suitable plug which is compatible with the socket
installed on the electricity supply which is powering this oven.
If a fixed appliance does not have a power cord and plug, or another
device that ensures disconnection from the mains, with an opening
distance of the contacts that allows complete disconnection under
the conditions of excessive voltage category III, such disconnection
devices must be provided in the power supply mains conforming to
the installation rules.
The omnipolar socket or switch must be easy to reach when the
appliance is installed.
N.B. The manufacturer declines all responsibility if all of the
above and the usual accident prevention regulations are not
observed.
18
TYPE AND MINIMUM DIAMETER OF THE CABLES
H05RR-F
3x1.5 mm²
H05VV-F
3x1.5 mm²
H05RN-F
3x1.5 mm²
H05V2V2-F 3x1.5 mm²
SASO
H05RR-F
3x2.5 mm²
H05VV-F
3x2.5 mm²
H05RN-F
3x2.5 mm²
H05V2V2-F 3x2.5 mm²

Publicidad

loading

Este manual también es adecuado para:

Fqmo 4505 mt x