Congratulations on your purchase
Congratulations on purchasing the latest energy-efficient ceiling fan technology. This fan uses DC current, allowing for very
high energy efficiency and high air circulation volume without added noise.
Energy efficiency: Your DC motor is the latest in fan design technology. It saves up to 70% of energy compared to fans with
traditional AC motors.
Silent operation: This fan's DC motor uses a stabilized current, which allows it to significantly reduce operating noise.
Low-heating operation: This DC motor is powered efficiently, reducing its operating temperature to under 50º C. This results
in better cooling than a standard AC motor and increases its durability.
Comfort: This fan with a DC motor incorporates a six-speed remote control that exceeds the traditional number of speeds in
AC motors, allowing for a greater variety of comfort levels.
Safety precautions
Follow these instructions carefully to enjoy maximum safety in the installation and operation of this equipment.
The minimum distance between the lamp and any illuminated objects must be greater than 1m.
The electrical installation of the ceiling fan must be carried out by an authorized electrician in order to be co-
vered by our warranty. Please remember to require your installer to test all the fan functions before you leave.
In case of any doubt from the installer, do not hesitate to contact us.
This device can be used by children aged 8 years and above and people with reduced physical, sensory or
mental abilities or lack of experience or knowledge, if they have been given appropriate supervision or training
<8
regarding the use of the device and they understand the dangers of its use. Children should not play with the
device. The cleaning and maintenance of the device should not be carried out by children without supervision.
The fan must be installed in such a way that the blades are more than 2,3m above the ground. Make sure that
there is a space of at least 30cm between the fan's blades and any wall or other obstacle that they could hit.
It is important to note that the greater the distance, the more efficient the air flow produced will be.
Before contacting the technical service, it is recommended to read the troubleshooting guide included in this manual.
Any action performed for the electrical connection of the device, such as its cleaning, must be carried out after
12
ensurin that the general power supply is disconnected, by removing the corresponding fuse or disarming the
protective switch in order to ensure total isolation of the power supply.
The fan must be installed at a location on the ceiling sch that the blades are at least 2.3 m above the floor and
OFF
OFF
300 mm from any object or wall. The mounting bracket must be attached to a ceiling structure that is capable
of supporting a minimum of 30 kg using the two screws provided. At least 30 mm of the length of the screws
must be screwed into the bracket. When deciding where to mount the fan, be sure that there is at least 30 cm
of space between the fan and any wall or other obstruction that the fan blades could collide with. The greater
Kg
this distance, the more effective the air flow produced.After the fan is mounted, be sure that the blades are
no less than 2.3 m above the ground
The ground wire of the fan must be connected to the earth network of the installation, to avoid any derivation
that may put people in danger.
Do not connect the fan's power supply to any dimmers, potentiometers, or light switches, as it will cause the
fan to malfunction and/or will damage the motor. For the electrical connection it is necessary to incorporate a
switch disconnector in accordance with the installation regulations, which ensures an omnipolar cut, directly
connected to the power terminals and must have a contact separation at all its poles, which provides total
disconnection under conditions of Category III overvoltage. The fan must be directly connected to a properly
protected installation circuit (magnetothermal differential switch with the adequate size for the fan's con-
sumption and technical specifications). Only use the fan's control to turn it on or stop it.
It is recommended to not use these types of fans along with gas installations simultaneously in the same room.
The fan must be not be moving and must have come to a complete stop before changing its direction of
rotation. This will prevent damage to its motor and to the control unit, when applicable.
Do not insert anything that could hit the fan's blades into its pathway while it is moving, as this could cause
damage to people, can damage the blades, and can offset the balance of the unit, causing vibrations and
wobbling.
After installing the fan, ensure that all fastenings are secure and tightened in order to avoid any noise caused
by loose elements.
CIF A28763647
+34 916774540
Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)
Due to the fan's movement, certain fastenings may become loose. Check all fastenings twice per year at a
minimum in order to ensure that they are sufficiently tight. If necessary, they must be retightened.
If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or similar
qualified personnel in order to avoid any malfunction.
Replaceable receiver
Do not refill the water tank with tap water, use only distilled water.
Maximum capacity of the water tank: 650ml.
Do not throw away electrical products together with household waste. We ask you to recycle the packaging
at the collection points provided for this purpose. Contact local authorities or your provider for recycling
advice. Thank you for recycling at the collection points provided for this manual.
Note: The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions
and situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be
included in all products. These factors can and must only be provided by the user who maintains and enjoys this fan.
Device technical spectifications
Nominal voltage and frequency
Protection category
Protection index
Word temperature
Maximun ceiling slope on which it can be installed
Weight
Nebulizer specifications
Power
Maximum tank capacity
Autonomy
Speed
Fan power (W)
Fan RPM
Fan airflow (m³/min)
Noise level (dB)
Service value SV ((m³ / min) / W)
Power consumption in standby mode (W)
Service value measurement standard
Preparing for installation
Note: The estimated installation time is 120 minutes. This product can only be installed by a certified electrician Carefully
separate the fan's parts, avoiding the use of cutters or blades that could scratch any part of it.
ATC: 916749481 - info@sulion.es / SAT : 916749483 - sat@sulion.es
220-240V~AC 50/60Hz
Clase I
IP44
-5
40ºC
9kg
13
3,8W
650ml
3600min
1
2
3
4
5
7
11,3
18
22,4
33
116
143
170
183
204
47
56
71
96
109
30
35
38
42
52
11,1
6,04
4,7
4,1
2,8
<0,5
EN 62879:2020
www.sulion.es

Publicidad

loading

Este manual también es adecuado para:

Mist