Lift up the burner housing sheet first in the
direction of arrow and then upward towards
the inside of the boiler and pull towards you
to take the sheet out of its place (figure 14)
Remove the mounting screws of the burner
and pull the burner by 15mm to release the
burner (figure 15).
If there is lighter and thermo element on the
burner, remove the fixing rings and take the
parts away from the burner.
After the burner is released, remove the
injector by help of 7's socket spanner and
mount the desired injector (see injector table).
Untighten the screw of the air adjusting screw
on the burner and bring the corres-ponding
letter of the desired gas type you want to
adjust to the same axis of the screw. Then
tighten the screw.
You should bring it to GPL indicated on the air adjusting
sheet for LPG.
For NG, you should bring it to 'N' on the air adjusting
sheet.
Leakage control
Open the valve or natural gas valve and apply soap water with ample foam to the
connection point to control for gas-tightness.
Never control by flame.
Final control
1. Plug the power cable into the socket and activate the fuse of the equipment.
2. Control the functions.
Placement
Place your product after you control the required power and gas connection. When
placing, make sure that the gas hose and power cable is not near the hot surface of
the product.
Segman
15
Figure
14
Figure 15
V.1