Inflation of VIKING RescYou
may be performed in three ways:
a: Automatic inflation:
The buoyancy chamber inflates within approx. 5
seconds after water immersion.
b: Manual inflation:
The lifejacket inflates with a strong pull of the
release handle at the right side of the lifejacket.
c: Oral inflation:
Open the protective cover and blow air into one
of the oral inflation tubes.
WARNING: Although it has been tested to
withstand excess pressure, never inflate the
lifejacket orally before automatic or manual
inflation.
4. MAINTENANCE
Maintenance of your lifejacket, as well as initial
testing, is essential to your safety in case of an
accident.The lifejacket must be handed in for
annual service at a VIKING certified servicing
station. Find your nearest servicing station on
VIKING-life.com.
NOTE: The bobbin in the automatic Halkey
Roberts
inflator must be replaced annually
®
from first use. Do not use bobbins more than
four years old. The production date is printed
on the bobbin itself.
4.1 CHECKING BEFORE USE
Check lifejacket before each use according to
manufacturer's instruction:
-
Check that the lifejacket is undamaged.
-
The indicator in the window must be green.
-
Check straps and buckles.
IMPORTANT: If the lifejacket is not intact, do not
use it. Make sure that the release line is placed
underneath the flap and the handle is placed in
the holder.
VIKING RESCYOU
™
Prime (PV9280)
TM
PRIME LIFEJACKET (PV9280)
4.2 CLEANING
Clean the lifejacket in mild soapy water only.
4.3 PACKING
Please see packing photos on page 42
1. Place the lifejacket on a table and unzip the
protective cover. Both sliders must be in an
open position at the bottom, left side of the
protective cover.
2. Fold up the bottom section on the left side
of the buoyancy chamber. It must have the
same length as the cover.
3. Fold the inner section on the left side
towards the middle.
4. Fold the outer section on the left side
towards the middle.
5. Zip the cover – starting at the bottom at the
left side – and zip up 20 cm. Close the hook
and loop fastener.
6. Fold the neck like a fan with the welding of
the neck part visible. Fold down the corner
at the top of the buoyancy on the left side.
7. Close the zipper until it is centre at the back
of the neckline.
8. Fold down the corner at the top of the
buoyancy on the right side
9. Fold up the bottom section on the right side
of the buoyancy chamber. It must have the
same length as the cover.
10. Fold the inner section on the right side
towards the middle.
EN