Descargar Imprimir esta página

Triton Blue TR-HAZER-1000 Manual De Usuario página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Timer on/off button.
2. Continuous output.
3. Manual override button.
4. Timer LED indicator (Illuminated Yellow when timer active).
5. Manual ready indicator (Illuminates Green when ready).
6. Power indicator (Illuminates red when power is on).
7. Adjust the amount of Haze released (between 0 – 100%).
DMX CHANNELS
CHANNEL
CHANNEL 1
CHANNEL 2
TRANSPORT INSTRUCTIONS
• 1. Always empty the big water tank before transport: open the water evacuation tap (5) on the
bottom of the fogger.
• 2. When the water tanks is empty: put the extendable PVC-hose in the big water tank.
• Important:make sure that the metal mouthpiece of the hose does not touch the piezo element of the
water tank, so that the piezo element will not be damaged.
• 3. To avoid spilling fog fluid: make sure that the fog liquid canister is not more than half full during
transport.
• 4. DO NOT TIP THE UNIT!!!
• 5. Always lock the brakes during transport!!!
MAINTENANCE AND CLEANING
• 1. IMPORTANT: Always set the output to Zero and wait for minimum 30 seconds before to switch off
the unit. This allows the unit to execute its cleaning process so all the remaining fluid is removed from
the internal circuits..
• 2. Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
• During inspection the following points should be checked:
• 3. All screws used for installing the device and any of its parts should be tightly fastened and may
not be corroded.
• 4. Housings,fixations and installations spots (ceiling, truss, suspensions) should be totally free from
any deformation.
• 5. The mains cables must be in impeccable condition and should be replaced immediately when even
a small problem is detected.
• Attention:We strongly recommend internal cleaning to be carried out by qualified personnel!
• Cleaning the fogger: To prevent obstructions in the heater, pump and tubes, the fogger should be
cleaned on a regular basis: every 100h of continuous operation is a good reference.
• Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
User Manual | TR-HAZER-1000 by Triton Blue | January 2024 | www.triton-blue.com | Exclusive Professional Use
Function
Fan speed control
Control amount of smoke/fog output
DMX value
0~255 from minus to plus
0~255 from minus to plus