EN
Torque Adjustment
See drawing 47132956 on Page 2.
To adjust the torque on these Twin Blade Impulse Wrenches, proceed as follows:
1. Remove the Socket Plug.
2. Rotate the Drive Shaft until the Torque Adjustment Screw is visible in the opening.
3. Using a 1.5 mm hex wrench, rotate the Torque Adjustment Screw clockwise to increase
torque. To decrease torque, rotate the Torque Adjustment Screw counterclockwise.
4. Replace the Socket Plug.
NOTICE
Make all final adjustments at the job.
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Office or Distributor.
EN-2
80206667_ed4