The building work must be finished in such a
way that the wood burner can expand during
operation: the brickwork must never be
supported on or against the sides of the
appliance. Leave a minimum expansion joint
of 0.5 cm on each side and at least 1 cm the
top of the front.
1. Fumes exhaust pipe Ø 200 or 150, according to model.
3.s2
2e. Entry of air into the chimney chamber by natural
convec on.
2.s Hot air outlet of the chimney chamber by natural
convec on.
2.s
3.e.1 Entry of air into the appliance convec on chamber
without the BOX op on.
3.s2
3.e.2 Entry of air into the appliance convec on chamber,
drawn in by fan system "BOX with ven lator".
3.s.1 Hot air outlet at the top of the front.
3.s.2 Op onal hot air outlet to other rooms driven by fans.
4. Op onal entry of air from the outside used for combus on
(op onal lower or rear connec on)
3.s1
3.e1
2.e