Descargar Imprimir esta página

ECOFOREST HC 2014 Manual De Instalación Y Mantenimiento página 36

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

The room sensor (  ) and the power wire are connected at the rear of the boiler as Shown in the diagram
that corresponds to the Aveiro model. You will know the boiler recognize it because the room temperature it will be
Shown in the control panel. If you connect a thermostat or contact instead of displaying the room temperature it will
be shown ( · ) indicating this that there is something connected in the communication port.
IF YOU HAVE ANY DOUBT ABOUT THE CONNECTION, THE INSTALLATION PRACTICABILITY OR THE USE OF
SUCH DEVICES, CONTACT YOUR DISTRIBUTOR WHO WILL INFORM YOU.
A BAD USE OR SETTING OF THESE DEVICES MAY CAUSE A MALFUNCTION OR EARLY DEGRADATION OF THE
BOILER.
Thermostat connection.
Power connection ~230/240V - 50Hz.
Thermostat.
Electrical cord ~230/240V - 50Hz.
5.
CLEANING AND MAINTENANCE.
To ensure the correct operation of your boiler, the following Cleaning and maintenance operations are
necessary at the indicated frequency. The boiler must always be cold.
The deterioration of the boiler parts by a lack of cleaning involves the loss of the two-year warranty offered
by ECOFOREST (see warranty section).
5.1.
Heat Exchanger.
Open the right side door, secured by 2 Torx head screws.
Pull the drawers of the rake-this shall be done while the glass door closed in order to reach the ash inside the
boiler. This shall be done every day when the boiler is cold.
Drawing 8
POWER WIRING AND ROOM THERMOSTAT.
DAILY CLEANING WHEN THE BOILER IS COLD.
35
Drawing 9

Publicidad

loading

Este manual también es adecuado para:

Hb 2014