3.5 Connection to network
The network supply must be: 230V – 50Hz.
Ignition
Attention!
It is necessary to supply the motor connections
with an omnipolar device for disconnection from
the electric network with a distance between contacts
of at least 3 mm (disconnecting switch, etc.)
Attention!
If several motors are connected, programming must
be carried out 1 motor at a time. The other motors
must be disconnected from the mains during
programming.
4. SYSTEM COMMISSIONING
Attention: the opening/closing limits are memorised in the installed motor and fully mounted roller blind/ awning.
Attention: for the 5-channel radio command, select the desired channel before proceeding with the programming.
Then, proceed just as for the 1-channel radio command.
4.1 One-channel remote control programming procedure
• SMS wireless tubular motor (without emergency manoeuvre function)
Power up: one long beep will be heard
and the motor will turn briefly in the
UP/DOWN (opening/closing) direction.
4.2 Five-channel remote control programming procedure
Remember to select the required channel using the RIGHT or LEFT button before programming each channel following the method
described above for the SMS models. The LED corresponding to the selected channel will light up.
Attention: For the 5-channel remote control (43901/005), the LEFT ◄ key (sliding up) and the RIGHT ► key (sliding down) have
the function of channel selection. Using the keys on the remote control (UP-STOP-DOWN), when all 5 LEDs are lit, the opening and
closing can be controlled centrally.
10
230V -
50Hz
Blue= Neuter
Brown Phase
Yellow/Green= Earth
Within 10 s, press the P2 button twice
and press the UP button once using a pencil.
A beep will be heard each time.
• The programming and adjustment of the electronic limit switches
takes place always and only with the radio control.
• On power up, the wired commands work, but only in step by step
mode.
• If the third limit switch has been programmed, it is possible, with the
UP & DOWN wired commands, to activate the third position by
operating them simultaneously for 5 seconds,
• For wired commands, only «buttons without self-restraint» N.O.
(normally open)
Three beeps will be heard
followed by the motor turning
briefly
in
the
up/down
(opening/closing) directions to
confirm
successful
programming: the motor will
turn up and down once.

Publicidad