1. INSTALLING RECEIVER IN CEILING FAN
A.Safety precautions
1. WARNING: HIGH VOLTAGE! Disconnect power
by removing fuse or switching off circuit breaker.
2. Do not use with solid state fans.
3. Electrical wire must meet all local and national
electrical code requirements.
4. Supply for fan must be 110/120 volt, 60Hz, 3.5A
5. Maximum fan motor amps: 1.0.
6. Maximum light watts: 180 incandescent or ballast and LED.
7. To Reduce the risk of shock, this fan must be installed
with a wall switch/control.
B. Installing receiver in fan
1. Remove power from the circuit.
2.Remove ceiling fan canopy from the mounting bracket.
3.Disconnect existing wiring between ceiling fan
and Supply in electrical junction box.
4.Make connections as follows, using the wire nuts
supplied.
FROM POWER SOURCE
AC 110~120 VOLT
60Hz 3.5AMPS.
RED/BLACK
ANT
CANOPY
If other fans or supply wires are different color, have this unit installed by qualified licensed electrician.
a.Push all connected wires up into junction box.
b.Lay the brown antenna wire on top of the receiver,and put the receiver into the mounting bracket.
c.Reinstall the canopy on the mounting bracket.
d.Restore power.
e.Install 1.5 volt battery. (To prevent damage to transmitter, remove the battery if not used for a long time).
f. Store the transmitter away from excessive heat or humidity.
g.This remote control unit is equipped with roll code combinations. In order to prevent possible interference from or to
other remote units such as garage door openers, car alarm or security system. If you find that your fan and light kit go on
and off without using your remote control, simply change the code combination in your transmitter and receiver
Remote controller
INSTRUCTION OF INSTALLATION AND OPERATION
Use wire connecting nuts supplied with the fan.
(FIG.2)
INPUT
WHITE
ANTENNA PUT AT OUTSIDE
OF CANOPY BOX CAN GET
OUTPUT
MORE OPERATION DISTANCE
Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
CODE
COM
LENARN
CODE
LENARN
CODE
ANT
(FIG.1)
TRANSMITTER
CAUTION: Ceiling Angle Shall Not Exceed 30 Degrees,
For Mounting Controller. Models GA012
CONNECT
TO
Red/Black receiver wire(AC IN L)......Red/Black supply wire
White receiver wire(AC IN N)......White supply wire
White receiver wire(TO MOTOR N)...White fan wire
Black receiver wire(TO MOTOR L)...Black fan wire
Blue receiver wire(FOR LIGHT)...Blue light wire
RECEIVER
FAN MUST KEEP AT THE
HIGH SPEED POSITION
F6354110V
ACL
INPUT
OUTPUT
RECEIVER
RECEIVER
(FIG.3)
CANOPY
LIGHT MUST KEEP AT THE
TURN ON POSITION
ACN