6.4.3. ENGINE STOPPAGE
Place throttle lever in the lower position
Put the switch in the ¨O¨ position.
6.5. CHECKING POINTS AFTER START UP
Check that there is no air in the aspiration hose.
Check that all the racors are correctly tightened and
that there are no water leakages on the main body of
the pump, through the racors or in the impulsion hose.
6.6. END OF USAGE
After using the machine, empty the water that is
inside the machine. To do this, unscrew the emptying
water screw and wait for the water to empty from the
machine. After this, screw back into place.
7. MAINTENANCE AND SERVICE
The objective of the maintenance and service is to
ensure that your machine works always in the best
possible conditions both in efficiency and security.
Follow the recommendations and the maintenance
periods included in this manual.
Turn off the engine before doing any adjustments,
change of accessories or storing the machine.
.
Action
Engine
oil
Air filter
Spark
plug
Deposit
filter
7.2. OIL CHANGE
To do the oil change, the oil must be hot to guarantee
that oil filters out correctly and quickly. If you are going
to change the oil, do so after using the machine if not
you will have to start the machine for a few minutes
prior to changing the oil so as to heat the oil.
Remember that the machine should not be started
with the pump empty (the pump must be filled up with
water).
Oil change:
1. Stop the machine.
2. Place the machine in a horizontal position and in
such a way that the oil drains out into a recipient.
Remember that this machine has a capacity for 0.6
l and therefore the recipient must have at least this
volume.
27/100
Check
level
Change
Check
Change
Check/
adjust