RECOMMENDATIONS ON THE CHANNELING OF CONVECTION AIR (CÓRDOBA CANALIZABLE AND CÓRDOBA
GLASS CANALIZABLE).
Convection air must always travel through insulated pipelines.
The maximum length for all pipes channeling air is of 5 meters. If the user needs longer pipes, he/she must install an
additional ventilation motor (see the diagram detailing the different parts.
Teide model: The pipes of the lateral convectors can not exceed 50cm.
Bolonia ducted model: It is possible to configure the convection air outlet through the front and / or
ducting pipe.
Convection air outlet selector.
4.17. Gas output must be located in a ventilated area, not in closed or half-closed areas e.g. garage, corridor, air
space of the house or places where gas may concentrate.
4.18. The external parts of the stove may reach high temperatures that might burn when touching; it is
recommended to use a non flammable grid to avoid risk of burn for children and old people.
The end of the gas outlet flex should remain higher than the stove's output. It is mandatory to install at least
two metres in length vertically to create natural current preventing smoke, odors or eventual cut of electric
supply.
The horizontal pipe must not be longer than 1 metre; greater lengths mean ash, condensation or corrosion
may build up in this area.
Faced with cut of electric supplies and unusual weather conditions (storms, strong winds) it is
recommendable to install an uninterruptible power supply (UPS) which we have available as an option. This
apparatus only feeds the exhaust vent.
4.19. Distances from doors, windows, ventilation grids or air input to the house or building:
A
Distance from ventilation grid.
B
Distance from ventilation grid.
C
Lateral side of a window.
D Top of a window.
E
Top of a door.
F
Lateral side of a door.
G Adjacent wall.
H Height from adjacent wall.
I
Adjacent building.
4.20. The minimum distance from gas outlet to ground shall be minimum 65cm, depending however on the
surface. Gas may burn grass, plants, trees located near the gas outlet. In the event that the stove outlet is
lower, suitable safety measures should be taken. The outlet pipe should never be below the extractor itself.
4.21. The distance between gas outlet and public pavement shall be minimum 2.20 m. See your local regulations.
SECURITY NORMS FOR GAS OUTPUT AND AIR INPUT.
500 mm
500 mm
1250 mm
650 mm
650 mm
1250 mm
300 mm
2300 mm
650 mm
35
Drawing 12
Drawing 13