5.3
Operating test
Press the control button and close the window, checking that:
a.
The window is completely closed. If it is not, check that the gap between the window and the frame is
bigger than or equal to 0 mm. If necessary, insert spacers so as to obtain the correct gap.
b.
The spindle is perfectly perpendicular to the window frame. If necessary adjust the fixing bracket by
using the screws and slots.
Having reached the correct closing position, press the control button and open the window in order to check that the
actuator runs freely over the full travel set up.
Having achieved the required opening run, press the control button again to close the window. Once the window
has completely closed, check that the screws, supports and fixings are tightened correctly, and that the seals are
sufficiently compressed.
Top-hung outward opening window / Solar shading: Closing the DIP-switch compartment.
Replace the rubber cap and screw up the retaining screw. Replace the plastic cover so that it cannot come out of
place. By connecting the actuator to the electrical supply, make the spindle go back into the position required.