Descargar Imprimir esta página

Brill VWS 60 Manual Del Usuario página 13

Partidor de maderas

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
Log splitter
There is a risk emanating from electrical current.
No other persons should be present within the
working area of the log splitter. Special heed
should be paid to children and animals.
The user of the unit bears responsibility for
accidents involving other persons or their prop-
erty. The working area should be kept free of
timber pieces and other objects – risk of stum-
bling.
Safety equipment
Motor circuit breaker
The motor circuit breaker switches the motor off
in the event of overloading of the log splitter. The
motor circuit breaker function should not be
deactivated.
Proceed as follows if the motor circuit breaker
deactivates the log splitter:
1. Disconnect the log splitter from the mains
power supply.
2. Remedy the cause of overloading.
3. Re-establish the power connection after
allowing the unit to cool for several minutes
and switch on the log splitter.
Connection cable
Only rubber cable complying with the H07RN-F
quality standard stipulated in VDE 0282 Part 14
with a wire cross section of min. 2.5 mm² should
be used.
The max. permissible cable length is 10 m. A
longer cable impairs the motor performance and,
consequently, the function of the log splitter.
The connection cable, plug and connection
socket should be free of damage.
Repairs to the connection cable, plug and con-
nection socket should only be realised by a
specialist electrical firm or workshop. A defective
connection cable (e.g. with cracks, cuts or bends
in the insulation) should not be used.
Plug connections should not be exposed to
damp or water.
Caution!
Do not damage or sever the connection
cable.
Proceed as follows in case of damage:
1. Disconnect the connection cable immediately
from the mains power supply.
Electrical requirements:
models
230 V/50 Hz current
Min. connection cable cross section = 2.5 mm²
Min. mains connection fuse protection = 16 A
LHS 7000 model
400 V 3~/50 Hz three-phase current
Mains connection and connection cable
5-wire: 3P+N+SL
Min. connection cable
cross section = 2.5 mm²
Mains connection fuse protection = 16 A
Direction of rotation of motor:
in direction of arrow (arrow on fan cover).
The direction of rotation should be
checked after every new power con-
nection.
Correct use
The log splitter is designed for private use in the
home and garden.
The log splitter is designed exclusively for the
following applications:
Splitting freshly-cut timber that does not
exceed the dimensions specified in the tech-
nical data.
Incorrect use
Splitting of timber containing metal compo-
nents such as nails, wire, metal braces, etc.
is prohibited
Operation in potentially-explosive atmos-
pheres is not permitted
Any other utilisation above or beyond correct
use is prohibited.
Unit description (Illus. A)
1
Transportation handle
2
Splitting blade
3
Control arms with levers and hand guards
4
Splitting table
5
Hydraulic oil tank
6
Stand feet
7
Motor
8
Switch/Plug socket combination
9
Splitter column
10 Swivel table
11 Engaging lever on swivel table
12 Splitting cross
13 Securing rubber bands
GB 2

Publicidad

loading

Productos relacionados para Brill VWS 60

Este manual también es adecuado para:

134174