1. IMPORTANT NOTE
Congratulations! You are the owner of a carefully designed and manufactured equipment. We
thank you for trusting on us and choosing our amplifier eGPA.
In order to obtain maximum operativity and perfect functioning order, it is most important to carefully
read all considerations taken into account in this manual before connecting this amplifier.
We recommend our authorised Technical Services if any maintenance task should be needed so
that optimum operation shall be achieved.
1.1. Precautions
The amplifier should have an earth connection in good conditions (earth resistance, Rg=30Ω or
less). The environment must be dry and dustless. Do not expose the unit to rain or water splashes, and
do not place liquid containers or incandescent objects like candles on top of the unit. Do not obstruct the
ventilation shafts with any kind of material. In case there is some type of intervention and/or connection-
disconnection of the amplifier, it is most important to previously disconnect the mains power supply.
Do not manipulate the output terminals to the loudspeakers when the amplifier is switched on,
there are voltages up to 400Vpp. The output cabling should be connected by a qualified
technician. Otherwise only use pre-made flexible cables. There are no user serviceable parts
inside the amplifier.
2. INTRODUCTION
The Ecler Essentials eGPA amplifier series offers the renowned professional reliability of Ecler
amplifiers at an affordable price. It consists of 3 models: one with a power of 2 x 150W RMS @ 4Ω
(eGPA2-150), a second one with a power of 4 x 150W RMS @ 4Ω (eGPA4-150) and a last one with a
power of 8 x 150W RMS @ 4Ω (eGPA8
standby and convection cooling, with a height of 1 rack unit.
Equipped with balanced inputs on Euroblock connectors. Outputs also feature Euroblock
connectors. It has an electronic limitation system to avoid signal saturation and a thermal protection, as
well as a protection system against overload.
2.1. Main features
- Easily accessible input attenuation controls on the front panel.
- Switchable auto standby circuit (energy saving mode when there is no input signal)
- Signal presence (SP), clipping (CLIP), protection against overload (PROT) and thermal
protection (TH) indicators.
- Built-in, always active anticlip circuit
- Operating mode selector: STEREO, MONO - BRIDGE
- Balanced inputs on Euroblock connectors
- Outputs on Euroblock connectors
- Accepts 8 or 4Ω loads (1 or 2 speakers (8Ω) in parallel)
4
150). All models use very high-performance technology, auto
-