OPERATION
DRAINING RECOVERY TANK
NOTE: When clean water bladder is empty, recovery
tank MUST be emptied.
FOR SAFETY: When servicing machine,
disconnect cord from wall outlet.
1. Turn all switches off.
2. Remove drain hose from holder, position hose
over floor drain and twist off knob to drain
(Figure 6.).
FIG. 6.
NOTE: If using a bucket to drain machine, do not use
same bucket for filling clean water bladder!
3. Replace knob tightly before cleaning again.
4. After final draining, remove rear clear lid and rinse
both tank and shutoff float screen thoroughly to
prevent odor buildup.
DRAINING SOLUTION TANK
1 . To drain remaining solution from solution tank.
Disconnect solution hose and attach bleeder hose
(bleeder hose supplied with machine).
2. Activate "PUMP" switch. Pump solution into a
empty bucket (Figure 7.).
ATTENTION: Before disconnecting solution hose
and replacing with bleeder hose, relieve water
pressure from tool before disconnecting hose.
Squeeze trigger for five seconds after turning off
switches.
6
Home
Find... Go To..
FIG. 7.
3. Rinse solution tank with clean water to prevent
odor build up. Run vacuum motor for 30 seconds
to discharge any moisture. Store extractor with
covers off to promote air circulation.
MAINTENANCE
To keep machine in good working condition, simply
follow machines daily, weekly and monthly
maintenance procedures.
WARNING: Hazardous Voltage. Shock or
electrocution can result. Always unplug machine
before servicing.
For ease of servicing, machine tank is hinged to pivot
away from chassis to allow access to inner
components. Make sure tanks are empty before
opening. To open extractor for servicing, follow these
steps:
a. Unplug extractor.
b. Unlatch front two latches.
c. Lift tank upward, away from chassis
(Figure 8.).
FIG. 8.
PX-1500LP (11–99)