_CombiPower_BA_DE-IT.book Seite 44 Freitag, 21. Oktober 2011 8:10 20
Technical description
4.3
Remote control
No. in
fig. 3,
Symbol
page 4
1
–
2
ON/OFF
3
4
▼
5
▲
6
7
ALARM
8
CHARGER
9
INVERTER
10
AC GRID
44
Explanation/function
Display: Shows operating messages or settings
To switch on the device: press briefly
To switch off the device: hold down (> 3 s)
Scroll through menu (level up; vertical scroll)
Hold down (> 2 s): open setup menu
Press briefly: scroll through menu (level down;
vertical scroll) or confirm value (ENTER function)
Scroll through menu (back; horizontal scroll) or
select a value
Scroll through menu (forward; horizontal scroll) or
select a value
LED for alarm display
Red light: 230 V over/undervoltage alarm, 12 V
over/undervoltage alarm, overload or fan mal-
function
Charging status LED:
Green light: charging
Off: not charging
Inverter status LED:
Green light: inverter mode
Red light: inverter fault
Off: inverter mode off
Mains voltage status LED:
Green light: AC voltage at input
Off: no
AC voltage at input
CombiPower
EN