Activated charcoal filter
• To install the charcoal filter, disassemble
the lid, introduce the filter in the position
provided and reassemble the lid.
• The carbon filter lasts from three to six
months depending on the particular
conditions of use.
• The activated carbon filter can neither
be washed nor regenerated. Once it is
exhausted, it must be changed.
• To replace the exhausted filter with a
new one, we will make in the same way
that
in
its
extracting the spent filter.
Electrical characteristics:
REFER TO RATING PLATE
This appliance has been designed, tested and
manufactured according to:
• Safety: EN/IEC 60335-1; EN/IEC 60335-
2-31, EN/IEC 62233.
To fix the extractor to the kitchen unit the
pattern on fig. 4 is used.
The lower part of the extractor must be
located at a minimum height of 50cm above
the hob for electric cookers and 65cm for
gas cookers. If the instructions of a gas
cooker indicate a greater distance these
must be observed.
To achieve optimum performance the length
of the outlet hose should not exceed 4
meters, or include more than two 90º angles
(elbows)
Although
venting
recommended, activated carbon filter may
be used, which allow the gas to be returned
to the kitchen through the outlet pipe.
26
assembly,
previously
to
the
outside
• A reduction in the extraction flow rate
may be observed in the hood with the
installation of carbon filters.
Changing Bulbs
• Remove the filters and the light bulbs
will be at sight.
• Take care to disconnect the mains
beforehand and that the bulbs to be
replaced are not hot.
• The maximum bulbs power is 40W.
• ILCOS D cod: DR-6-H-E14-37 or ILCOS
D cod: HSGSB/C-28-230-E14
• Performance: EN/IEC 61591; ISO 5167-1;
ISO 5167-3; ISO 5168; EN/IEC 60704-1;
EN/IEC 60704-2-13; EN/IEC 60704-3;
ISO 3741; EN 50564/IEC 62301.
• EMC: EN 55014-1 / CISPR 14-1; EN
55014-2 / CISPR 14-2; EN/IEC 61000-3-
2; EN/IEC 61000-3-3.
To evacuate via the upper part, an external
evacuation conduit is needed and the
evacuation lever to be located in the ―E‖
position (Fig. 5).
The small (anti-return) outlet hose is located,
ensuring that the remaining outlets are duly
plugged.
To allow re-circulation through the active
carbon filter the evacuation lever is located
in the ―I‖ position. Then the activated
carbon
filter
corresponding groove.
is
CAUTION: Accessible parts may become hot
when it is used with cooking appliances.
is
introduced
in
the