Descargar Imprimir esta página

Kärcher IVR 60/30 Sc H ACD Manual página 27

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 64
Illustration M
16.Close the safety filter bag tightly with the
attached cable tie.
17.Remove the safety filter bag from the
dirt receptacle.
18.Clean the interior of the dirt receptacle
with a moist cloth.
19.Dispose of the used safety filter bag in
dust-tight bag in accordance with statu-
tory regulations.
Illustration E
20.Fit the dirt receptacle in the device.
Illustration D
WARNING
Improper handling when locking the dirt
receptacle
Risk of crushing
Under no circumstances should you hold
your hands between the dirt receptacle and
filter ring or allow them to come close to the
lifting mechanism while locking it.
Lock the dirt receptacle by operating the le-
vers with both hands.
21.Lock the dirt receptacle with the levers.
22.Fit the pressure equalisation hose on
the dirt receptacle
Switching on the device
1. Plug the mains plug into the socket.
2. Switch on the device at the trigger.
Illustration N
3. Start vacuuming.
Reading the minimum volumetric
A gauge is mounted on the front of the de-
vice that shows the vacuum intensity (see
chapter Device description).
The table shows the maximum vacuum in-
tensity value. This value depends on the
unit performance and the suction hose
used.
ATTENTION
Suction loss
If the specified value is exceeded, the air
speed in the suction hose drops below 20
m/s.
Clean the main filter when the value is
reached, or sooner (see chapter Cleaning
the main filter.
flow
Replace the main filter if the value is not
significantly reduced by cleaning (see
chapter Replacing the main filter).
Power Hose diameter Value
3.0 kW DN40
3.0 kW DN50
4.0 kW DN40
4.0 kW DN50
 Clean the main filter before or when the
specified value is reached.
Cleaning the main filter
Note
Clean the main filter regularly to avoid a
loss of suction power.
Illustration O
1. Move the main filter cleaning handle
back and forth several times to clean the
filter.
Switching off the device
1. Switch off the device at the On/Off
switch.
2. Empty and clean the dirt receptacle.
3. Remove the accessory and clean and
dry if necessary.
Each time after use
Emptying the dirt receptacle
The dirt receptacle must be emptied as
necessary and after each use.
1. Switch off the device and disconnect
from the mains supply.
2. Clean the main filter.
3. Remove the dirt receptacle from the de-
vice and replace the dust bag (see chap-
ter Replacing the dust bag) or the safety
filter bag (see chapter Replacing the
safety filter bag).
Note
Only move the dirt receptacle on its rollers.
Do not use a crane, forklift or similar
means.
English
200 mbar (20
kPA)
150 mbar (15
kPA)
226 mbar (22.6
kPA)
216 mbar (21.6
kPA)
27

Publicidad

loading

Este manual también es adecuado para:

Ivr 100/30 sc h acdIvr 100/40 sc h acd