Descargar Imprimir esta página

Ryobi RTS12 Manual Del Operador página 8

Sierra de mesa de 254 mm (10 pulg.)
Ocultar thumbs Ver también para RTS12:

Publicidad

Idiomas disponibles

Idiomas disponibles

DOUBLE INSULATION
Double insulation is a concept in safety in electric power
tools, which eliminates the need for the usual three-wire
grounded power cord. All exposed metal parts are isolated
from the internal metal motor components with protecting
insulation. Double insulated tools do not need to be
grounded.
WARNING:
The double insulated system is intended to protect
the user from shock resulting from a break in the tool's
internal wiring. Observe all normal safety precautions to
avoid electrical shock.
NOTE: Servicing of a product with double insulation requires
extreme care and knowledge of the system and should
be performed only by a qualified service technician. For
service, we suggest you return the tool to your nearest
authorized service center for repair. Always use original
factory replacement parts when servicing.
ELECTRICAL CONNECTION
This tool has a precision-built electric motor. It should be
connected to a power supply that is 120 V, AC only (normal
household current), 60 Hz. Do not operate this tool on
direct current (DC). A substantial voltage drop will cause a
loss of power and the motor will overheat. If the tool does
not operate when plugged into an outlet, double check the
power supply.
POLARIZED PLUGS
See Figure 1.
To reduce the risk of electric shock, this tool has a polarized
plug (one blade is wider than the other). This plug will fit in
a polarized outlet only one way. If the plug does not fit fully
in the outlet, reverse the plug. If it still does not fit, contact
a qualified electrician to install the proper outlet. Do not
change the plug in any way.
EXTENSION CORDS
When using a power tool at a considerable distance from
a power source, be sure to use an extension cord that has
the capacity to handle the current the product will draw. An
undersized cord will cause a drop in line voltage, resulting in
overheating and loss of power. Use the chart to determine
the minimum wire size required in an extension cord. Only
round jacketed cords listed by Underwriter's Laboratories
(UL) should be used.
ELECTRICAL
When working outdoors with a product, use an extension
cord that is designed for outside use. This type of cord is
designated with "WA" or "W" on the cord's jacket.
Before using any extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
**Ampere rating (on tool faceplate)
Cord Length
25'
50'
100'
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
WARNING:
Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on lumber,
tools or other obstructions while you are working with a
power tool. Failure to do so can result in serious personal
injury.
WARNING:
Check extension cords before each use. If damaged
replace immediately. Never use product with a damaged
cord since touching the damaged area could cause
electrical shock resulting in serious injury.
8 - English
0-2.0
2.1-3.4
3.5-5.0
5.1-7.0 7.1-12.0
Wire Size (A.W.G.)
16
16
16
16
16
16
16
14
16
16
14
12
POLARIZED
PLUG
12.1-16.0
14
14
14
12
10
Fig. 1

Publicidad

loading

Este manual también es adecuado para:

Rts12t