WARNINGS AND GENERAL PRECAUTIONS
DANGER OF ELECTROCUTION!
• The device is designed to control other electrical devices and operate in their housings. Faulty connection or use can result in fire or electric
shock.
• Even when the device is turned off, voltage can be present at its terminals. Any maintenance introducing changes to the configuration of con-
nections or the load must be always performed with a disabled fuse.
• All works on the device can be performed only by a qualified and licensed electrician in complience with national regulations.
• Always use the same power source for L and IN terminals.
CAUTION!
• Failure to observe recommendations included in this manual can be dangerous or cause law violation.
• Check the operating/maintenance manual of the device which is to be controlled, to make sure the connection is safe and allowed.
• Don't connect devices which aren't compliant with the specifications or relevant safety standards.
• Don't install the device in metal boxes or on metal surfaces to ensure best range of operation.
• Don't expose this product to moisture, water or other liquids. Don't use in bathrooms and other rooms with high humidity.
• This product is designed for indoor use only. Don't use outside.
• This product isn't a toy. Keep away from children and animals!
2
PRODUCT DESCRIPTION
The remotely operated NICE SingleSmart-Control is designed to turn electrical devices or circuits on and off.
SingleSmart-Control enables the control of one device or a circuit.
The compact size of this product enables its installation in the housings of other devices.
The device can be controlled either using the Z-Wave® network or with buttons connected directly to the device.
3
BASIC ACTIVATION OF THE DEVICE
1. Switch off the power supply.
2. Connect as shown in Figure 1 below.
3. Switch on the power supply.
4. Set the main Z-Wave® controller in the add mode.
5. Click the B-button quickly, three times.
6. Wait for the device to be added in the system.
7. Adding is confirmed by the Z-Wave® controller.
2
100-240V AC
24-30V DC
S1 S2
L
N
Q
IN
B
Figure 1: Example connection of SingleSmart-Control
1
– device/system housing
2
– electrical device
B – maintenance button