LevelSmart Installation
Quick Start Guide
Step 1 - Install the Valve
Plumb the valve into the designated water fill line, or "T" it into the
pool return plumbing after the filter and pump equipment from
a nearby water source. You can use a water spigot, or "T" from a
nearby irrigation line or similar. Add
a pressure regulator if desired.
Fill the pool to the desired
water level.
Make sure the valve solenoid
is in the "OFF" position (see right).
Step 2 - Install & Connect Valve Controller
For best results, mount the Valve Controller in a protected area
out of direct sunlight and rain exposure. This component is
weather-proof rated, but is always better tucked away from the
elements if possible.
Mount the valve controller using the mounting screws provided in
the accessory pack.
Use the wire nuts provided to connect the Valve Controller wires to
the valve wires.
Connect the Valve Controller to the power transformer with the
two pin plug, then plug into power source.
All 3 LED lights will repeatedly flash in sequence from the bottom
to the top. This indicates that the unit is in pairing mode. Move on
to the next step while this is taking place.
Step 3 - Connect Antennas to Valve Controller
Connect all antennas and tighten them.
Place antenna tip in desired mounting position off the ground and
8-12 inches away from any metal.
Step 4 - Pair Sensor & Valve Controller
Make sure Valve Controller is flashing in a sequence indicating it is
in pairing mode.
Take Sensor to pool; set on coping above desired install location.
Remove magnet. Leave sensor on coping and watch the pairing
process take place at Valve Controller. The yellow 'ACTION' light
will flash for about 2.5 minutes.
Once Pairing is successful, a solid green LED will be seen on the
Valve Controller.
If pairing is not successful, place the Valve Controller into pairing
mode by unplugging and plugging it back in. Then, place the
magnet on the sensor for at least 15 seconds and remove. Once
removed, repeat step 4.
Step 5 - Adhere Sensor and Mount Antenna
Clean/scrub the area where the Water Level Sensor is to be
mounted.
Mount the water level sensor where the desired water is about 0.5
- 1.5-inches up on the sensor.
Knead the epoxy thoroughly and spread on the dry back suface of
the sensor. Firmly press the sensor against the mounting surface
for at least 90 seconds, being sure that the sensor is sitting 0.5 -
1.5-inches into the desired water level.
Step 6 - Set Your Water Level
After the Water Level Sensor has adhered, use the magnet to set
the water level. NOTE: Water must be at desired level to set. To
do so, place the magnet in the bottom-right corner of the Level
Sensor, and hold it there for two-seconds before removing it. A
green light will appear on the sensor and flash three times. This
indicates the calibration has begun. A green SENSOR light will also
flash on the Valve Controller for about one-minute, as the water
level is set.
This step will conclude with a solid green SENSOR light on the Valve
Controller. If additional water isn't required, shut off the water
supply or turndown the flow control knob for this 7-minute period.
As long as the green SENSOR LED is visible, the unit has paired, and
been set, successfully.
Step 7 - Adjust Flow Control
IMPORTANT FOR SPA APPLICATIONS: If LevelSmart is being installed
to a smaller body of water, such as a spa or small swimming pool,
make sure to reduce the flow control knob (the middle knob)
so that the amount of water is reduced on each fill. To do so, it's
recommended that the flow control knob is tightened down half-
way.
See Back Cover for Installation Checklist
Desired water level should
be within blue band
English