Indicators
Indicator
Fastening
accept indicator
Fastening
reject indicator
Power indicator
Signal strength
indicator
Setting the beep volume
Set the beep volume with the volume switch.
Low volume
(Approx. 75 dB)
NOTE
The beep mode setting is configured while the Assembly Qualifier is connected to a
computer. See page 9.

Using the software

1. Turn on the Assembly Qualifier's power switch.
All indicators will turn on and off, leaving only the power
indicator on.
2. Use the registered tool to perform fastening work.
Status of tool's fastening
confirmation indicator
Green
Red
Green
Fastening accept signal received.
Off
No fastening accept signal is being received.
Red
Fastening reject signal received.
Off
No fastening reject signal is being received.
Blue
Power on (receive mode)
Off
Power off
Flashing blue Tool registration standby mode
Yellow
Strong signal
Orange
Medium-strength signal
Red
Weak signal
Flashing red
Signal received during double-count prevention time.
Off
No fastening signal is being received.
OFF
High volume
(Approx. 90 dB)