Descargar Imprimir esta página

Premium levella PRN165DX Manual De Instrucciones página 11

Vitrina refrigerador comercial de dos puertas
Ocultar thumbs Ver también para PRN165DX:

Publicidad

Idiomas disponibles

Idiomas disponibles

to the correct specification. At all times, the manufacturer's maintenance and service
guidelines shall be followed. If in doubt, consult the manufacturer's technical department for
assistance.
 Detection of flammable refrigerants: Under no circumstances shall potential sources of ignition
be used in the searching for or detection of refrigerant leaks. A halide torch (or any other
detector using a naked flame) shall not be used.
Ⅶ、Caution for Using
1. Unpack all packages before using the cooler. Don't slant it over more than 60°, while movingit.
2. When initial operation, the cooler should run emptily about two hours before storing food init.
3. The control button could adjust the temperature inside the cooler. Generally, the temperature
setting of 5℃ is appropriate
4. To save energy, the door should not be frequently opened or left open for a long time.
5. The surface and the inside of the cooler should be dry and clean. Long term moisture will
cause the cooler rust slowly. (There will be some stains on the surface.)
6. Periodical cleaning is suggested for your reference. Generally, 30-45 days once is the best. When
cleaning, it is best to wipe the inside and the surface of the cooler with a soft cloth with neutral
soap or detergent.
Caution: To ensure safety, the power plug must be pulled out before cleaning.
Ⅷ、 Cleaning of the unit
For cleaning the unit's internal plastic parts, use a light solution of soap and water. Do not apply hard
chemical detergents on the plastics as they may lose their brightness or even get deformed.
The same applies to the external metallic surfaces. The use of hard chemicals could harm the painting
of the metallic surfaces, thus affecting the sanitary protection of the unit.
Ⅸ、Ordinary Trouble and Remedies:
Please refer to the below trouble shooting lists to overcome any minor problems that occur during
operations.
Trouble
No voltage
Lamp
not lighting
Have voltage
Compressor
works
orderly
Condenser
fan
Compressor
Not running
does not
work
Reason
Fuse breaking off
Poor connection
between the plug and
socket
lamp has poor contact
or worn down
Lamp switch has poor
contact
Condenser fan broken
Remove condenser fan Change condenser fan
down
Thermostat is not set
to the work position
Thermostat terminal is
not connected
properly
Check
Check fuse
The connection lease
Repair or change socket
or not
Check the circuit and
Tighten the connection
lamp
Tighten the connection
Check the switch
or change a new switch
Revolve the thermostat
Check the position of
the thermostat knob
Check the thermostat
Reconnect the terminal
terminal
11
Solution
Change fuse
or change a new lamp
knob to the operating
position
Remark
Ask professional to
maintain.
Ask professional to
maintain.

Publicidad